Case Wheel Loader Fault Codes List: E52D to P0659
Page 15 of 19 of the full Case Wheel Loader fault code list (1,859 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.
Case Wheel Loader codes E52D to P0659
- E52DECU Internal: Error Sensor Supplies Voltage Tracker
- E536Engine Speed Limitation Via Fuel Injection Cut Off Is Active
- E53DECU Internal Failure - Undervoltage Monitoring Error
- E55DECU Temperature Sensor Error Detected
- E56DECU EEPROM Memory Failure - EEPData1 Block
- E5B1ECU Internal Failure - Accelerator Pedal Position Sensor
- E5DDECU Internal Failure - Injection Quantity Correction
- E61DECU Internal Failure - SPI Communication Error
- E62D12V Sensor Supply 1 Voltage Is Too High
- E63DECU Internal Failure - WDA Is Not Working Correctly
- E698eVGT Motor Effort Too High
- E69DECU Internal Failure - Timeout In The Shutoff Path Test Error
- E6DDECU Internal Failure - Rail Pressure Plausibility
- E6DENH3 Sensor Open Or Short In Measuring Cell Circuit
- E71DECU Internal Failure - ROM Error
- E72D12V Sensor Supply 1 Voltage Is Too Low
- E73DECU Internal Failure - Alarm Task Period Error
- E79DECU Internal Failure - Overvoltage Monitoring Error
- E7DDECU Internal Failure - Torque Request Comparison
- E7DENH3 Sensor Open Or Short In Ground Circuit
- E812ECU Internal Failure - Calculated Engine Speed
- E81DECU Internal Failure - 'WDA Active' Reported Due To Errors In Query/Response Communication
- E82DInternal 12V Supply Voltage Is Too High
- E83DECU Internal Failure - Positive Test Failure
- E8DDECU Internal Failure - Torque Request Due To Fuel Pressure Exceeds Maximum Torque Limit
- E91DECU Internal Failure - 'ABE Active' Reported Due To Undervoltage Detection
- E92DInternal 12V Supply Voltage Is Too Low
- E98EUpstream NOx Sensor Values Are Not Plausible
- E9DDECU Internal Failure - Torque Request Due To Rail Control Exceeds Maximum Torque Limit
- E9DENH3 Sensor Open In Heater Circuit Causing Underheating
- EA1DECU Internal Failure - 'ABE Active' Reported Due To Overvoltage Detection
- EADDECU Internal Failure - Torque Request Exceeds Maximum Torque Limit
- EADENH3 Sensor Open Or Short In Temperature Cell Circuit
- EB1DECU Internal Failure - 'WDA/ABE Active' Reported
- EBDDECU 5 Volt Supply Voltage Is Higher Than Expected
- EBDENH3 Sensor Open Or Short In Trim Resistor Circuit
- EC36ECU Internal Failure - Fuel Injection Energizing Time Is Not Plausible
- ECDDECU 5 Volt Supply Voltage Is Lower Than Expected
- ED2DCAN Communication Failure - External Torque/Speed Checksum And Counter
- ED36ECU Internal Failure - Fuel Injection Energizing Phase Is Not Plausible
- EE1DECU Internal Failure - Software Resets In DSM1
- EE36Fuel Injection Correction Has Exceeded A Minimum Limit
- EF1DECU Internal Failure - Software Resets In DSM
- F176Missing Adjustment Value Programming For Injector In Cylinder 1
- F18FDEF Level Too Low Is Active - Stage 1
- F1A2Engine Over Speed Condition Detected
- F1EFTorque Limitation Cause By Turbocharger Protection
- F245Fuel Pressure Relief Valve Is Forced To Open, Perform Pressure Increase
- F276Missing Adjustment Value Programming For Injector In Cylinder 5
- F28FDEF Level Too Low Warning Is Active - Stage 2
- F2EFStrong Torque Limitation From Engine Protection Active
- F345Fuel Pressure Relief Valve Is Forced To Open, Perform Pressure Shock
- F376Missing Adjustment Value Programming For Injector In Cylinder 3
- F3A2Torque Limitation Due To Excessive Coolant Temperature
- F3EFStrong Torque Limitation From Injection System Active
- F445Fuel Pressure Relief Valve Is Open
- F476Missing Adjustment Valve Programming For Injector In Cylinder 6
- F49FSCR Inducement: Level 1 (Torque Reduction), Triggered By DEF Dosing Interruption Fault
- F4A2Torque Limitation Due To Excessive Exhaust Gas Temperature
- F4EFTorque Limitation Caused By Engine Brake
- F523Engine Coolant Temperature Has Exceeded The Pre-Warning Threshold
- F561ECU After Run Power Interruption
- F576Missing Adjustment Value Programming For Injection In Cylinder 2
- F59FSCR Inducement: Level 3 (Creep Mode), Triggered By DEF Dosing Interruption Fault
- F5A2Torque Limitation Due To Excessive Fuel Temperature
- F623Engine Coolant Temperature Has Exceeded The Warning Threshold
- F676Missing Adjustment Value Programming For Injector In Cylinder 4
- F69FSCR Inducement: Warning, Triggered By DEF Dosing Interruption Fault
- F6A2Torque Limitation Due To Excessive Intake Air Temperature
- F6EFTorque Limitation Caused By Performance Limiter
- F7A2Torque Limitation Due To Excessive Oil Temperature
- F7EFTorque Limitation Caused By SCR Catalyst Protection
- F836Number Of Injections Is Limited By System
- F895Rail Pressure Reduction By Blank Shots During After Run Aborted
- F8A2Torque Limitation Due To Turbocharger Protection After Start
- F936Exceeded The Number Of Injections For A Given Engine Speed
- FA9FSCR Inducement: Level 1 (Torque Reduction), Triggered By DEF Quality Fault
- FABFRemaining DEF Is Below The Empty Threshold
- FAEFTorque Limitation Active
- FB54Intake Air Humidity Sensor Voltage Is Higher Than Expected
- FB9FSCR Inducement: Level 3 (Creep Mode), Triggered By DEF Quality Fault
- FBBFInducement System Is Locked Due To 3 Detections In 40 Hours. The System Must Be Reset Using The Service Tool Screen "Engine Restart Counter Reset"
- FC9FSCR Inducement: Warning, Triggered By DEF Quality Fault
- FD8FTorque Limitation Is Active
- FD9FSCR Inducement: Level 1 (Torque Reduction), Triggered By Tampering Fault
- FE9FSCR Inducement: Level 3 (Creep Mode), Triggered By Tampering Fault
- FF9FSCR Inducement: Warning, Triggered By Tampering Fault
- P0071Ambient Temperature CAN Receive Signal: (Barometric Pressure Not in Range)
- P0426Plausibility of Catalyst Temperature Sensors - Plausibility Error
- P0427Catalyst Temperature Sensor Circuit Low - Before Catalyst
- P0428Catalyst Temperature Sensor Circuit High - Before Catalyst
- P042BCatalyst Temperature Sensor Circuit Range/Performance
- P042CCatalyst Temperature Sensor Circuit Low - After Catalyst
- P042DCatalyst Temperature Sensor Circuit High - After Catalyst
- P0562Battery Voltage Sensing (Electrical) - Below Lower Limit
- P0563Battery Voltage Sensing (Electrical) - Above Upper Limit
- P0600Ambient Temperature CAN Receive Signal: (Ambient Air Temperature Not in Range)
- P062FEEPROM/Checksum Failures - EEPROM Detection Error or Codierwort Error (P062F)
- P065812 Volt Supply for Dosing Module - Below Lower Limit
- P065912 Volt Supply for Dosing Module - Above Upper Limit
Other Case machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- New Holland Tractor3,475 codes
- FPT3,033 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- New Holland Combine2,274 codes
- John Deere Tractors1,884 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
- Deutz1,684 codes
- Perkins1,523 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.