Diagnostics
New Holland Tractor Fault Codes List & Code Lookup
Look up 3,475 New Holland Tractor fault codes and error codes, in plain English. Find your code below, then hand it to the AI assistant for what it means and the first things to check.
Full New Holland Tractor fault code list
A generic J1939 reader pulls 812 of these; the other 2,663 need New Holland Tractor tooling to read in full. Every listed code is below, in code order, 100 to a page.
Codes on file
3,475
Readable as J1939 SPN/FMI
812
New Holland Tractor-specific
2,663
- 1Control Panel Disconnected from CAN Bus Line or CAN Bus Line Failure
- 10+5V Potentiometer Supply Short to Ground
- 10001Front Suspension Pump-Not-Tank Solenoid Valve Open Circuit or Short to Ground
- 10002Front Suspension Rod - Side Solenoid Valve Open Circuit or Short to Ground
- 10003Front Suspension Piston - Side Solenoid Valve Open Circuit or Short to Ground
- 10004Front Axle Position Sensor - Threshold Higher Than Set Limit
- 10005Front Axle Position Sensor - Threshold Lower Than Set Limit
- 10006Front Suspension Will Not Raise
- 10007Front Suspension Will Not Lower
- 10008Front Suspension Piston Pressure Sensor out of Range High
- 10009Front Suspension Piston Pressure Sensor out of Range Low
- 10010Chassis Accelerometer - Voltage Too Low (Short Circuit to Ground/Open Circuit)
- 10011Chassis Accelerometer - Voltage Too High (Short Circuit to 5V)
- 10012Front Suspension Rod Side Pressure Cannot Raise the Axle
- 10013Front Suspension Piston Side Pressure Will Not Raise the Axle
- 10014Front Suspension Not Calibrated
- 10015Front Suspension Lock Valve Solenoid Open Circuit or Short to Ground
- 10016Front Suspension Enable Switch Error
- 10017Front Suspension Switch CAN Data Not Available
- 10019Front Suspension Rod - Side Solenoid Over Current
- 1002Raise Hitch Valve Coil Short to 12 Volts or Raise Hitch Valve Coil Circuit Failure
- 10020Front Suspension Control - Enable Solenoid Valve - Short Circuit or Low Current
- 10021Front Suspension Control - Lower Solenoid Valve - Short Circuit or Low Current
- 10022Front Suspension Control - Raise Solenoid Valve - Short Circuit or Low Current
- 10023Front Suspension Control - Lockout Solenoid Valve - Short Circuit or Low Current
- 10024Front Suspension Not Calibrated
- 10025Front Suspension Control - Pressure Will Not Raise
- 10026Front Suspension Control - Pressure Will Not Lower
- 10027Suspension Will Not Raise Fault
- 10028Front Suspension Control - Suspension Will Not Lower
- 10029Front Suspension Control - Position Sensor - Out of Range High
- 1003Radar Sensor and Transmission Output Speed Sensor - Speed Difference Too High
- 10030Front Suspension Control - Position Sensor - Out of Range Low
- 10031Front Suspension Control - Raise Pressure Sensor - Out of Range - High
- 10032Front Suspension Control - Raise Pressure Sensor - Out of Range - Low
- 10033Front Suspension Control - Lower Pressure Sensor - Out of Range - High
- 10034Front Suspension Control - Lower Pressure Sensor - Out of Range - Low
- 10035Controller Memory Error - Loss of Valid Radar Configuration Information
- 10036Controller Memory Error - Loss of Valid Timer Information
- 10037Controller Memory Error - Loss of Valid Implement Width Information
- 10038Front Suspension Enable Switch Error
- 10039Front Suspension Switch CAN Data Not Available
- 1004Wheel Speed (Transmission Output Speed) Sensor - Signal Too High
- 10040Pump Not Tank Solenoid Over Current
- 10041Rod Solenoid Over Current
- 10042Piston Solenoid Over Current
- 10043Lock Solenoid/Solenoid - Relay Over Current Lockout Solenoid Valve
- 1005Lower Hitch Valve Coils - Open or Short to Ground
- 1006Electronic Draft Control Low Side Driver Stuck On Failure
- 10060AD12VM Voltage Low
- 10061AD12VF3 Voltage Low
- 10062AD12VF1 Voltage Low
- 1007Hitch Slip Control Potentiometer - Signal Too High
- 1008Low Side of Raise Solenoid Connected Permanently to Ground
- 1009Hitch Position Control Switches - Implausible Signals or Signal at Key On
- 10091Controller Internal Failure
- 10099Front Suspension Wrong Configuration
- 1010Voltage too Low on the Maximum Arms Raise Potentiometer
- 1011Voltage too High on the Maximum Arms Raise Potentiometer
- 1012Voltage too Low on the Lowering Speed Potentiometer
- 1013Voltage too High on the Lowering Speed Potentiometer
- 10145 Volt Reference is above the Upper Voltage Limit
- 10155 Volt Reference is below the Lower Voltage Limit
- 1016Left-Hand Draft Pin Sensor - Signal Too Low
- 1017Left-Hand Load Sensing Pin - Signal Too High
- 1018Rockshaft Position Potentiometer is Outside Normal Operating Range Hitch Position Potentiometer 77 1019 - Upper Limit Potentiometer Failure
- 10198 V Reference Voltage for Draft Pin Sensors - Voltage Too Low
- 10208 V Reference Voltage for Draft Pin Sensors - Voltage Too High
- 1021Load Command Received from CAN Data Bus Indicates Failure Condition
- 1022Single Draft Pin Sensor Failed When Configured for One Draft Pin Sensor
- 1023Two Draft Pin Sensors Failed When Configured for Two Draft Pins
- 1024Communication Lost with the Instrument Controller
- 1025Voltage too Low on the Working Depth Control Potentiometer
- 1026Voltage too High on the Working Depth Control Potentiometer
- 1027Lift Arm Position Sensing Control Voltage Low (Short or Open Circuit)
- 1028Voltage too High on the Lift Arms Position Potentiometer
- 1029Remote Hydraulic Control Selection Switch 5 Failure
- 103Odd Clutch Solenoid or its Wiring Failed Open or Shorted to Ground
- 1030Right Draft Pin Voltage is Outside the Normal Operating Range
- 1031Left Draft Pin No Load Offset Voltage Outside Normal Range
- 1032Ground Speed Failure, Value Received from Data Bus Indicates Failure Condition
- 1033Hitch Draft Control Potentiometer - Signal Too Low
- 1034Slip Enable Switch Failure
- 1035Percent Slip Error
- 1036The Armrest Control Module Indicates the Inching up Switch is Faulty or Not Available
- 1037The Armrest Control Module Indicates the Inching down Switch is Faulty or Not Available
- 1039PTO ON/OFF Control Switch Failure
- 104Even Clutch Solenoid or its Wiring Failed Open or Shorted to Ground
- 1040Lift Not Calibrated
- 1042Lowering Limit Potentiometer Not Set on Maximum Value
- 1043Lowering Speed Potentiometer Not Set on Maximum Value
- 1044Set Position/Draft Control Potentiometer Not in Position
- 1049Wheel Speed (Transmission Output Speed) Sensor - Open Circuit
- 105C1-2 Clutch Solenoid or its Wiring Failed Open or Shorted to Ground
- 10535 V Reference Voltage for Electronic Draft Control (EDC) Voltage Too High
- 10545 V Reference Voltage For Electronic Draft Control (EDC) Voltage Too Low
- 10598 Volt Reference Error (Draft Load Pins)
- 106the AUX/Hitch/PTO Controller Has Received the Electro Hydraulic #5 Control Extend Switch Data in the Error State
- 1063Open Circuit on the Lowering Control Solenoid Valve
- 1064Open Circuit on the Lifting Control Solenoid Valve
Other New Holland machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- FPT3,033 codes
- Case IH2,992 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- John Deere Tractors1,884 codes
- Case Wheel Loader1,859 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
- Deutz1,684 codes
- Perkins1,523 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.