Deutz codes 1345 to 1559
- 1345Timeout Error of CAN-Receive-Frame MSMon_FidFCCTO; Master-Slave CAN communication faulty.
- 1347Fuel pump error cause unknown
- 135Timeout error (PCK2PCK) for CAN-Receive-Frame AT1IGCVol1.
- 1357Error Memory Slave Reports FID MSMMonFC2 (Collective Error)
- 136Customer Specific Temperature Sensor 1: Erratic, Intermittent Or Incorrect
- 1368Error Memory Slave Reports FID MSMMonFC3 (Collective Error)
- 137Timeout error of CAN-Receive-Frame AT1OG1. NOX sensor (SCR-system downstream cat; DPF-system downstream cat).
- 1378Sensor air pump air pressure; plausibility error.
- 1379Sensor exhaust has back pressure burner; plausibility error.
- 138Hand Throttle Pedal Sensor: Erratic, Intermittent Or Incorrect
- 1380Sensor differential pressure (DPF); plausibility error.
- 1381Rail pressure safety function is not executed correctly.
- 1389Burner Shut Off Value; Open Circuit
- 139Customer Specific Temperature Sensor 2: Errormode Not Identifiable
- 1390Burner Shut Off Valve; powerstage over temperature.
- 1392Burner Shut Off Valve; short circuit to ground.
- 1395Burner Temperature Sensor; Plausibility Error
- 1398Physical range check high for ECU temperature.
- 14Digital Accelerator Pedal Sensor (PWM): Erratic, Intermittent Or Incorrect
- 140Customer Specific Temperature 2: Erratic, Intermittent Or Incorrect
- 1402Sensor exhaust gas temperature OxiCat downstream (normal operation); plausibility error.
- 1403Sensor exhaust gas temperature OxiCat downstream (regeneration); plausibility error.
- 141Calibration message 1 of the after catalyst NOx sensor has failed.
- 1411Waste Gate Actuator; Internal Error
- 1412Waste Gate Actuator; EOL Calibration Not Performed Correctly
- 1413Wastegate actuator calibration deviation too large, recalibration required.
- 1414Wastegate; status message from ECU missing
- 1415Waste Gate Actuator; Blocked
- 1416Wastegate actuator; over temperature (> 145°C)
- 1417Waste Gate Actuator; Over Temperature (>135 °C)
- 1418Wastegate actuator; operating voltage error.
- 142Timeout error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2.
- 1423Warning threshold for an internal actuator error exceeded, < 4L EGR.actuator und >4L Air Intake Flap
- 1424Shutoff Threshold For An Internal Actuator Error Exceeded, EGR.Actuator/Shut Off Threshold For An Internal Actuator Error Exceeded, Air Intake Flap
- 1425Air temperature within air filter box above maximum physical value.
- 1426Environment temperature below minimum level
- 143Internal Hardware Monitoring: Errormode Not Identifiable
- 1431CAN message PROEGRActr; plausibility error.
- 1432Timeout Error Of CAN-Receive-Frame ComEGRActr - Exhaust Gas Recirculation Positioner
- 1434CAN; Not Used
- 1435ComRxCustSysReacMin
- 1436Disc Separator; Open Circuit
- 1437Disc Separator; Power Stage Over Temperature
- 1438Disc Separator; short circuit to battery
- 1439Disc Separator; short circuit to ground
- 144Internal Hardware Monitoring: Errormode Not Identifiable
- 1440EGR actuator; internal error
- 1441EGR actuator; calibration error
- 1442EGR actuator; status message "EGRCust" is missing
- 1443EGR actuator; due to overload in Save Mode
- 145Internal Hardware Monitoring: Errormode Not Identifiable
- 1455Temperature during stand-still main phase too low or too high
- 1458High exhaust gas temperature EGR cooler downstream; warning threshold exceeded.
- 146Internal Hardware Monitoring: Errormode Not Identifiable
- 147Internal Hardware Monitoring: Errormode Not Identifiable
- 1481DPF system; operating voltage error
- 1482CAN message ComMS_Sys7 not received from slave
- 1484Master ECU And Slave ECU Have Been Identified As The Same Types
- 1485Master ECU and Slave ECU data sets or software are not identical
- 1486SCR Main Relay; Open Circuit (Only CV56B).
- 1488SCR main relay; short circuit to battery (only CV56B)
- 1489SCR main relay; short circuit to battery (only CV56B)
- 149Charge Air Temperature Sensor: Erratic, Intermittent Or Incorrect
- 1490SCR Reversing Valve; Open Circuit
- 1491SCR reverting valve; over temperature
- 1493SCR reverting valve; short circuit to ground.
- 15Digital Accelerator Pedal Sensor (PWM): Unusual Frequency, Pulse Or Period
- 150Charge Air Temperature: Errormode Not Identifiable
- 1505Fuel low pressure pump; error pressure build up
- 1523Exhaust Gas Recirculation AGS Sensor; Signal Not Plausible
- 1524Exhaust Gas Recirculation AGS Sensor; Sensed exhaust mass value above maximum physical value.
- 1525Exhaust Gas Recirculation AGS Sensor; Sensed exhaust mass value below minimum physical value.
- 1526Exhaust Gas Recirculation AGS Sensor; Plausibility Error, AGS Sensor Has Not Passed The Burn Off Process
- 1527Exhaust Gas Recirculation AGS Sensor; Temperature off EGR mass not plausible.
- 1528Pressure sensor upstream turbine, plausibility error
- 1529(Upstream NOx-Sensor) Diagnostic Fault Check for invalid upstream NOx value (Sensor self diagnostic DFC set by Deutz-SW) NOx-Sensor before SCR-Cat: Invalid upstream NOx value.
- 153Injector Cylinder Bank 1: Errormode Not Identifiable
- 1530(Downstream NOx-Sensor) Diagnostic Fault Check for invalid downstream lambda value (Sensor self diagnostic DFC by Deutz-SW)
- 1531(Upstream NOx-Sensor) Diagnostic Fault Check for invalid upstream lambda value (Sensor self diagnostic DFC set by Deutz-SW)
- 1532(Downstream NOx-Sensor) Diagnostic Fault Check for invalid downstream NOx value (Sensor self diagnostic DFC by Deutz-SW)
- 1533NOx Sensor Downstream SCR-CAT, Sensor Internally Open Circuit
- 1534NOx sensor downstream SCR-CAT, sensor internally short circuit.
- 1535NOx sensor upstream SCR-CAT, sensor internally open load.
- 1536NOx sensor upstream SCR-CAT, sensor internally short circuit.
- 1537NOx sensor downstream SCR-CAT, lambda value above upper physical threshold
- 1538NOx sensor downstream SCR-CAT, lambda value below lower physical threshold
- 1539NOx sensor upstream SCR-CAT, lambda value above upper physical threshold
- 154Injector Cylinder Bank 1: Out Of Calibrated Range
- 1540NOx sensor upstream SCR-CAT, lambda value below lower physical threshold
- 1541(Downstream NOx-Sensor) Diagnostic Fault Check for downstream NOx value over maximum limit (DFC set by Deutz-SW)
- 1542NOx-Sensor downstream SCR-CAT, NOx value below minimum value.
- 1543NOx-Sensor downstream SCR-CAT, NOx value above maximum value.
- 1544NOx sensor upstream SCR-CAT, NOx value below lower physical threshold.
- 1545Plausibility error between pressure downstream turbine (PTrbnDs) and ambient air pressure (EnvP)
- 155Injector Cylinder Bank 2: Errormode Not Identifiable
- 1555Relay Urea backflow line heater: broken wiring detected (open load) In-line engine: SCR-backflow line (K29) V-engine: Master: SCR-suction/backflow line (K32.1) Slave: SCR-suction/backflow line (K32.2)
- 1556SCR main relay not connected
- 1557SCR Heater Pressure Line; Open Circuit
- 1558SCR heater main relay; short circuit to battery
- 1559SCR heater main relay load side (K31) on heating valve (Y31), Short cut to ground.
Other Deutz machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- New Holland Tractor3,475 codes
- FPT3,033 codes
- Case IH2,992 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- New Holland Combine2,274 codes
- John Deere Tractors1,884 codes
- Case Wheel Loader1,859 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.