- 156Injector Cylinder Bank 2: Out Of Calibrated Range
- 1560Relay DEF Suction Line: Broken Wiring Detected (Open Circuit) Row Engine: SCR Suction Line (K28) V-Engine: Master: Common SCR-Suction Line (K28) Slave: Common SCR Back Flow Line (K29)
- 1561SCR Heater Supply Module; Open Circuit
- 1562SCR Heater Tank; Open Circuit
- 1565Pressure sensor upstream SCR-CAT, pressure above upper physical threshold.
- 1566Pressure sensor upstream SCR-CAT, pressure below lower physical threshold
- 1569Pressure Sensor Upstream SCR-CAT; Short Circuit Battery Or Open Circuit
- 157Internal Hardware Monitoring: Erratic, Intermittent Or Incorrect
- 1570Pressure sensor upstream SCR-CAT; short circuit ground
- 1579SCR measurement heater output stage; short circuit battery or open load
- 158Internal Hardware Monitoring: Defective Component
- 1581DEF supply module, heater temperature above upper physical threshold
- 1582DEF supply module, heater temperature below lower physical threshold
- 1585DEF supply module, temperature above upper physical threshold.
- 1586DEF supply module, temperature below lower physical threshold
- 159Injector 1: Errormode Not Identifiable
- 1593DEF tank, DEF level above upper physical threshold
- 1594DEF tank, DEF level below lower physical threshold
- 1597Pressure downstream turbine, plausibility error
- 1598Pressure sensor upstream SCR-CAT, plausibility error
- 16Ambient Air Pressure Sensor (In ECU): Erratic, Intermittent Or Incorrect
- 160Injector 1: Out Of Calibrated Range
- 161Injector 2: Errormode Not Identifiable
- 1616Passive regeneration of DPF; Plausibilitätsfehler DPF differential pressure sensor and a further sensor or actuator CRT system defective
- 1617Passive regeneration of DPF; DOC error Temperature sensor us, and ds. Doc simultaneously defect.
- 1619DEF Error Lamp; Open Circuit
- 162Injector 2: Out Of Calibrated Range
- 1620Urea Error Lamp; temperature over limit
- 1621Urea Error Lamp; short circuit battery
- 1622Urea Error Lamp; short circuit ground
- 163Injector 3: Errormode Not Identifiable
- 1630Fuel low pressure upstream fuel low pressure pump not plausible
- 1631Fuel low pressure upstream fuel low pressure pump, pressure above maximum warning threshold.
- 1632Fuel low pressure upstream fuel low pressure pump, pressure above maximum shut off threshold
- 1633Fuel low pressure upstream fuel low pressure pump, pressure below minimum shut off threshold
- 1634Fuel low pressure upstream fuel low pressure pump, pressure below minimum warning threshold
- 1635Maximum standstill time reached; oil exchange request ignored.
- 1639SCR System, pressure build up not possible.
- 164Timeout error of CAN-Receive-Frame EBC1.
- 1646DEF supply module, time for defrosting too long
- 1647DEF tank, time for defrosting too long
- 165Injector 4: Errormode Not Identifiable
- 1654Urea Tank Signal to HMI for indicating the Urea Tank-Level 1 (Urea tank volume ratio low threshold 1)
- 1655DEF tank, DEF level below first warning threshold
- 1656DEF tank, DEF level below second warning threshold
- 1658Control Of The SCR System; If The Start Stop Counter (EPA-Counter) Exceeds The Threshold SCRCtl_ctEngStrtStopThresh_C. This Counter Will Increment Only Once In Each Driving Cycle In Case Of An SCR Error. If The Counter Reaches The Threshold, The DFC Will Be Set To Inhibit The Engine Start. Engine Will Not Be Started, Because of EPA-Counter.
- 1659Timeout error of CAN-Transmit-Frame A1DOC
- 166Injector 4: Out Of Calibrated Range
- 1660Threshold Error of CAN-Transmit-Frame AT1S
- 1661Timeout error of CAN-Transmit-Frame SCR2
- 1662Timeout error of CAN-Transmit-Frame SCR3
- 1663Timeout error of CAN-Transmit-Frame DPFBrnAirPMPCtl
- 1664Timeout error of CAN-Transmit-Frame ComDPFBrnPT
- 1665Timeout error of CAN-Transmit-Frame ComDPFC1
- 1666Timeout error of CAN-Transmit-Frame ComDPFHisDat.
- 1667Timeout error of CAN-Transmit-Frame ConDPFTstMon
- 1668Timeout error of CAN-Transmit-Frame ComEGRMsFlw (EGR steller)
- 1669Timeout error of CAN-Transmit-Frame ComEGRTVActr (EGR actuator)
- 167Timeout error of CAN-Transmit-Frame EEC3.
- 1670Timeout error of CAN-Transmit-Frame ComETVActrTO
- 1671Timeout Com Intake Throttle Valve Actr.
- 1672Timeout error of CAN-Receive-Frame ComRxCM1
- 1673Timeout error of CAN-Receive-Frame ComRxCustSCR3
- 1674Timeout error of CAN-Receive-Frame ComRxDPFBrnAirPmpCtl
- 1675Timeout error of CAN-Receive-Frame ComRxDPFBrnAirPmp
- 1676Timeout error of CAN-Receive-Frame ComRxDPFCtl.
- 1677Timeout error of CAN-Receive-Frame ComRxEGRMsFlw1 (EGR actuator)
- 1678Timeout error of CAN-Receive-Frame ComRxEGRMsFlw2 (EGR actuator)
- 1679Timeout Error Of CAN-Receive-Frame ComRxEGRTV Actr (EGR Actuator)
- 168Timeout error of CAN-Transmit-Frame EEC3VOL1. Engine send messages
- 1680Timeout error of CAN-Receive-Frame ComRxETVActr
- 1681Timeout error of CAN-Receive-Frame ComRxlTVActr
- 1682Timeout error of CAN-Receive-Frame ComRxSCRHtDiag
- 1683Timeout Error Of CAN-Receive-Frame ComRxTrbChActr (Waste Gate Actuator)
- 1684Timeout Error Of CAN-Receive- Frame ComRxUQSens (DEF Quality)
- 1685Timeout error of CAN-Receive-Frame ComSCRHtCtl
- 1686Timeout error of CAN-Receive-Frame ComTxAT1IMG
- 1687Timeout Error Of CAN-Receive-Frame ComTxTrbChActr (Waste Gate Actuator)
- 169Timeout error of CAN-Transmit-Frame EEC3VOL2. Engine send messages.
- 1698HMI system; set if restore button blocked
- 1699DPF, ash load exceeds the shutoff threshold
- 17Air Heater Relay: Errormode Not Identifiable
- 170Injector 6: Out Of Calibrated Range
- 1700DPF, ash load exceeds the warning threshold.
- 1701DPF, soot load exceeds the shutoff threshold.
- 1702DPF, soot load exceeds the service request threshold.
- 1703DPF soot load exceeds the warning threshold.
- 1705Timeout error of CAN-Receive-Frame ComRxEBC2.
- 1706Fan control; time out for fan governing
- 1708Fan; Short Circuit Battery Or Open Circuit
- 1709Fan; short circuit to ground
- 171Timeout error of CAN-Receive-Frame ComEngPrt. Engine Protection.
- 1710Fan; In/Outlet Valve 1; Open Circuit
- 1712Fan; in/outlet valve 1; short circuit battery
- 1713Fan; In/Outlet Valve 1; Open Circuit Ground
- 1714Fan; In/Outlet Valve 2; Open Circuit
- 1716Fan; in/outlet valve 2; short circuit battery
- 1717Fan; In/Outlet Valve 2; Open Circuit Ground
- 1718Fan; fan control; angle sensor defect
- 1719Fan; fan control; fan or valve defect
Other Deutz machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- New Holland Tractor3,475 codes
- FPT3,033 codes
- Case IH2,992 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- New Holland Combine2,274 codes
- John Deere Tractors1,884 codes
- Case Wheel Loader1,859 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.