  • 16128High Pressure Switch (-) Input Shorted To Ground
  • 16129High Pressure Cycling Error (2 In 1 Minute)
  • 16130Low Pressure Switch (+) Input Shorted To Power
  • 16131Low Pressure Switch (+) Input Shorted To Ground
  • 16132Low Pressure Switch (-) Input Shorted To Power
  • 16133Low Pressure Switch (-) Input Shorted To Ground
  • 16134Low Pressure Switch Open For Greater Than 1 Minute
  • 161ADownstream SCR Catalyst Temperature Sensor Voltage is Higher Than Expected
  • 1636Number of Desired Injections Exceeds Threshold
  • 165DECU Temperature Sensor Voltage is Higher Than Expected
  • 16B1Foot Throttle Sensor - Signal Above Range Maximum
  • 16E5Prefilter Fuel Pressure Sensor Voltage is Lower Than Expected
  • 17CAT2 Flap Closing Switch Disconnected Or Flap Not Closed
  • 17195CAN B Bus Off Passive Failure
  • 17296EGR Valve : Current Limitation Active
  • 17297DFC For Valve Drift At Closed Position
  • 17301EGR Valve: Permanent Governor Deviation For Valve, Max
  • 17302EGR Valve: Permanent Governor Deviation For Valve, Min
  • 17303EGR Valve: Open Load Error For Powerstage
  • 17305EGR Valve: Over Temperature Error For H-Bridge
  • 17306EGR Valve: Short Circuit To Battery On Out1 Error For H-Bridge
  • 17307EGR Valve: Short Circuit To Battery On Out2 Error For H-Bridge
  • 17308EGR Valve: Short Circuit To Ground On Out1 Error For H-Bridge
  • 17309EGR Valve: Short Circuit To Ground On Out2 Error For H-Bridge
  • 17310EGR Valve: Short Circuit Over Load Error For H-Bridge
  • 17312EGR Valve: Under Voltage Error For H-Bridge
  • 17322DFC For Valve Position Sensor Voltage SRC High
  • 17323EGR Valve: DFC For Valve Position Sensor Voltage SRC Low
  • 17337Hydrocarbon Level 2 Exceeded
  • 17345Glow Plugs: DFC For Faulty Diagnostic Data Transmission Or Protocol Error
  • 17347Glow Plugs: Over Temperature Error On ECU Powerstage For Glow Plug Low Voltage System
  • 17348Glow Plugs: Over Temperature Error On ECU Powerstage For Glow Plug Low Voltage System
  • 17349Glow Plugs: Short Circuit To Battery Error For Low Voltage System
  • 17350Glow Plugs: Short Circuit To Ground Error For Low Voltage System
  • 17359Array Of DFCs For Short Circuit In i+1th Glow Plug_0
  • 17360Array Of DFCs For Short Circuit In i+1th Glow Plug_1
  • 17361Array Of DFCs For Short Circuit In i+1th Glow Plug_2
  • 17362Array Of DFCs For Short Circuit In i+1th Glow Plug_3
  • 17377MI1 Injection Quantity Is Low
  • 17378MI1 Energizing Time Is Low
  • 17379Measured Injection Closing Time Exceeds A Limit
  • 17380Measured Injection Closing Time Exceeds A Limit
  • 17381Measured Injection Closing Time Exceeds A Limit
  • 17382Measured Injection Closing Time Exceeds A Limit
  • 17383IMA Type_0 Mismatch
  • 17384IMA Type_1 Mismatch
  • 17385IMA Type_2 Mismatch
  • 17386IMA Type_3 Mismatch
  • 17387Chip Error In The Injector CY33x Power Stage Component
  • 17403Urea Supply Module: Reporting Error If Relay Is Stuck At Closed Position
  • 17404Urea Supply Module: Reporting Error If Relay Is Stuck At Open Position
  • 17405DFC Used To Evaluate Filter Clog
  • 17406Plausibility Of The Absolute Difference Between The Battery Voltage And Power Stage Voltage Of Backflow And Suction Line Heater
  • 17407Urea Supply Module: Plausibility Of The Absolute Difference Of Battery Voltage And The Powerstage Of The Pressure Line
  • 17408Urea Supply Module: Plausibility Of The Absolute Difference Between The Battery Voltage And Power Stage Voltage Of Supply Module Heater
  • 17409Urea Supply Module: Reporting The Leakage In The System During No Dosing
  • 17410Error In Dosing Valve Plausibility At Low Voltage
  • 17411Urea Supply Module: Defective Pressure Reduction
  • 17412Urea Supply Module: High Threshold For Pressure Sensor Plausibility
  • 17413Urea Supply Module: Low Threshold For Pressure Sensor Plausibility
  • 17414Urea Supply Module: No Load Error
  • 17415Urea Supply Module: Over Temperature Error
  • 17416Urea Supply Module: Short Circuit To Battery Error
  • 17417Urea Supply Module: Short Circuit To Ground Error
  • 17420SRC High For Urea Pump Module Pressure Sensor
  • 17421SRC Low For Urea Pump Module Pressure Sensor
  • 17422Timer Error Of ECU Off Time Counter
  • 17423SCR Inducement: Level 1 (Torque Reduction), Triggered By EGR Valve Blocked Fault
  • 17425SCR Inducement: Warning, Triggered By EGR Valve Blocked Fault
  • 17427SRC High For Air Temperature Sensor
  • 17428SRC Low For Air Temperature Sensor
  • 17429DFC Is Set If The Cold Start Is Detected
  • 17442Intake Throttle Valve: Permanent Governor Deviation For Valve, Max
  • 17443Intake Throttle Valve: Permanent Governor Deviation For Valve, Min
  • 17444Intake Throttle Valve: Open Load Error For Powerstage
  • 17445Over Current Error For H-Bridge
  • 17446Intake Throttle Valve: Over Temperature Error For H-Bridge
  • 17447Intake Throttle Valve: Short Circuit To Battery On Out1 Error For H-Bridge
  • 17448Intake Throttle Valve: Short Circuit To Battery On Out2 Error For H-Bridge
  • 17449Intake Throttle Valve: Short Circuit To Ground On Out1 Error For H-Bridge
  • 1745Fuel Pressure Relief Valve Has Reached Maximum Allowed Open Time
  • 17450Intake Throttle Valve: Short Circuit To Ground On Out2 Error For H-Bridge
  • 17451Intake Throttle Valve: Short Circuit Over Load Error For H-Bridge
  • 17453Intake Throttle Valve: Under Voltage Error For H-Bridge
  • 17465Open Load Error In Powerstage of Urea Dosing Valve Actuator
  • 17466Short Circuit To Battery Error In Powerstage Of Urea Dosing
  • 17467Short Circuit To Battery Error In Highside Powerstage Of Urea Dosing Valve Actuator
  • 17468Short Circuit To Ground Error In Lowside Powerstage Of Urea Dosing Valve Actuator
  • 17469Short Circuit To Ground Error In Highside Powerstage Of Urea Dosing Valve Actuator
  • 17470HCU - Heater Control Unit For Reagent Dosing Lines: FET Error
  • 17476Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17477Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17478Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17479Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17480Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17481Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17482Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17483Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17484Diagnostic Fault Check For Supply Module Temperature Duty Cycle In Failure Range
  • 17485Urea Supply Module: No Load Error On Low Powerstage For Urea Back Flow Pump