HeavyEquipmentFix
Ask

Deutz Fahr Fault Codes List: 1160 to 130

Page 2 of 11 of the full Deutz Fahr fault code list (1,004 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.

Deutz Fahr codes 1160 to 130

  • 1160Zero Fuel Calibration Injector 3 (In Firing Order); Maximum Value Exceeded
  • 1161Zero Fuel Calibration Injector 4 (In Firing Order); Maximum Value Exceeded
  • 1162Zero Fuel Calibration Injector 5 (In Firing Order); Maximum Value Exceeded
  • 1163Zero Fuel Calibration Injector 6 (In Firing Order); Maximum Value Exceeded
  • 1164Zero Fuel Calibration Injector 1 (In Firing Order); Minimum Value Exceeded
  • 1165Zero Fuel Calibration Injector 2 (In Firing Order); Minimum Value Exceeded
  • 1166Zero Fuel Calibration Injector 3 (In Firing Order); Minimum Value Exceeded
  • 1167Zero Fuel Calibration Injector 4 (In Firing Order); Minimum Value Exceeded
  • 1168Zero Fuel Calibration Injector 5 (In Firing Order); Minimum Value Exceeded
  • 1169Zero Fuel Calibration Injector 6 (In Firing Order); Minimum Value Exceeded
  • 117Fuel Balance Control Integrator Injector 3 (In Firing Order); Minimum Value Exceeded
  • 1170Internal Software Error ECU
  • 1171Customer Oil Temperature; Signal Un-Plausible
  • 1173SCR Tamper Detection; Derating Timer Below Limit 1
  • 1174SCR Tamper Detection; Derating Timer Below Limit 2
  • 1175Urea Quality; Derating Timer Below Limit 1
  • 1176Urea Quality; Derating Timer Below Limit 2
  • 1177Urea Tank Level; Derating Timer Below Limit 1
  • 1178Urea Tank Level; Derating Timer Below Limit 2
  • 118Fuel Balance Control Integrator Injector 4 (In Firing Order); Minimum Value Exceeded
  • 1180Physical Range Check High for Battery Voltage
  • 1181Physical Range Check Low for Battery Voltage
  • 1182Physical Range Check High for Intake Air Temperature
  • 1183Physical Range Check Low for Intake Air Temperature
  • 1187Bad Quality of Reduction Agent Detected
  • 119Fuel Balance Control Integrator Injector 5 (In Firing Order); Minimum Value Exceeded
  • 1192Over Temperature Error on Burner Shut Off Valve
  • 1193Physical Range Check High for Exhaust Gas Temperature Upstream Turbine
  • 1194Physical Range Check Low for Exhaust Gas Temperature Upstream Turbine
  • 120Fuel Balance Control Integrator Injector 6 (In Firing Order); Minimum Value Exceeded
  • 121Engine Shut Off Demand Ignored
  • 1216Glow Plug Control Release Line; Short Circuit Error
  • 1217Glow Plug Control; Internal Error
  • 1219DPF Wasn't Regenerated, Power Reduction Phase 1 (Manual Regeneration Request)
  • 122Shut Off Request From Supervisory Monitoring Function
  • 1220DPF Wasn't Regenerated, Power Reduction Phase 2 (Manual Regeneration Request)
  • 1221DPF Wasn't Regenerated, Warning Condition (Manual Regeneration Mode)
  • 1222Camshaft and Crankshaft Speed Sensor Signal Not Available on CAN
  • 1223Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Open Load
  • 1224Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Over Current
  • 1225Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Over Temperature
  • 1226EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Short Circuit to Battery (A02)
  • 1227EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Short Circuit to Battery (A67)
  • 1228EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Short Circuit to Ground (A02)
  • 1229EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Short Circuit to Ground (A67)
  • 1230Actuator Error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Overload by Short Circuit
  • 1231Actuator Error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Power Stage Temperature Due to High Current
  • 1232Actuator Error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); Voltage Below Threshold
  • 1239UB6; Short Circuit to Battery Error of Actuator Relay 7
  • 1240UB7; Short Circuit to Battery Error of Actuator Relay
  • 1243Charging Lamp; Open Load
  • 1244Charging Lamp; Over Temperature
  • 1245Charging Lamp; Short Circuit to Battery
  • 1246Charging Lamp; Short Circuit to Ground
  • 1247Air Pump; Air Lines Blocked
  • 1248Air Pump; CAN Communication Lost
  • 1249Air Pump; CAN Communication Interrupted No Purge Function Available
  • 125Time Out Error of CAN - Transmit - Frame AmbCon; Weather Environments
  • 1250Air Pump; Internal Error
  • 1251Air Pump; Power Stage Over Temperature
  • 1252Air Pump; Operating Voltage Error
  • 1253Burner Dosing Valve (DV2); Blocked Closed
  • 1254Air Pressure Glow Plug Flush Line; Below Limit
  • 1255Burner Operation is Interrupted Too Often
  • 1256HCI Dosing Valve (DV1); Blocked Closed
  • 1257HCI Dosing Valve (DV1); Blocked Open
  • 1258HFM Sensor; Electrical Fault
  • 1259Amount of Air is Not Plausible to Pump Speed
  • 126Time Out Error of CAN - Receive - Frame AMB; Ambient Temperature Sensor
  • 1260Calculated Amount of Air is Not Plausible to HFM Reading
  • 1261Air Pump; Over Current
  • 1262Burner Shut Off Valve; Blocked Closed
  • 1263Burner Fuel Line Pipe Leak Behind Shut Off Valve
  • 1264Burner Shut Off Valve; Blocked Open
  • 1265Spark Plug Control Unit (SPCU); Electrical Fault
  • 1266Spark Plug Control Unit (SPCU); Internal Error
  • 1267Fuel Balance Control Integrator Injector 7 (In Firing Order); Maximum Value Exceeded
  • 1268Fuel Balance Control Integrator Injector 8 (In Firing Order); Maximum Value Exceeded
  • 1269Fuel Balance Control Integrator Injector 7 (In Firing Order); Minimum Value Exceeded
  • 127DLC Error of CAN - Receive - Frame AT1IG1 NOX Sensor (SCR-System Upstream Cat; DPF-System Downstream Cat); Length of Frame Incorrect
  • 1270Fuel Balance Control Integrator Injector 8 (In Firing Order); Minimum Value Exceeded
  • 1279Time Out Error of CAN - Receive - Frame DM19Voll; NOX Sensor Upstream
  • 128Time Out Error of CAN - Receive - Frame AT1IG1; NOX Sensor Upstream
  • 1283Time Out Error of CAN - Receive - Frame DM19Voll; NOX Sensor Downstream
  • 1285Time Out Error of CAN - Receive - Frame ComMS_SyslTO (Error Memory Slave); Master-Slave Internal CAN Message
  • 1286Time Out Error of CAN - Receive - Frame ComMS_Sys2TO (Error Memory Slave); Master-Slave Internal CAN Message
  • 1287Time Out Error of CAN - Receive - Frame ComMS_Sys3TO (Error Memory Slave); Master-Slave Internal CAN Message
  • 1288Time Out Error of CAN - Receive - Frame ComMS_Sys4TO (Error Memory Slave); Master-Slave Internal CAN Message
  • 1289Time Out Error of CAN - Receive - Frame ComMS_Sys5TO (Error Memory Slave); Master-Slave Internal CAN Message
  • 129DLC Error of CAN - Receive - Frame ATllGlVol NOX Sensor (SCR-System Upstream Cat; DPF-System Downstream Cat); Length of Frame Incorrect
  • 1290Time Out Error of CAN - Receive - Frame ComMS_Sys6TO (Error Memory Slave); Master-Slave Internal CAN Message
  • 1291Master-Slave CAN; Message - Counter - Error of CAN - Receive - Frame ComMSMoFOvR
  • 1292Master-Slave CAN; Checksum - Error of CAN - Receive - Frame ComMSMoFOvR
  • 1293Master-Slave CAN; Message - Length - Error of CAN - Receive - Frame ComMSMoFOvR
  • 1294Time Out Error CAN Message ComMSMoFOvRlTO Error Memory Slave
  • 1295Message Copy Error in the Master/Slave Data Transfer
  • 1297CAN - Transmit - Frame ComTrbChActr "Bus Off-Status"; Wastegate
  • 1298CAN - Transmit - Frame ComTrbChActr Disable Error; Wastegate
  • 1299CAN - Transmit - Frame ComTrbChActr Plausibility Error; Wastegate
  • 130Time Out Error of CAN - Receive - Frame ATllGlVol; NOX Sensor (SCR-System Upstream Cat; DPF-System Downstream Cat)
Looking for a different Deutz Fahr code?Search the full fault-code database, or hand the code to the AI assistant for a plain-English explanation.

Other Deutz machine types