New Holland Tractor codes 17403 to 18027

  • 17403Urea Supply Module: Reporting Error if Relay is Stuck at Closed Position
  • 17404Urea Supply Module: Reporting Error if Relay is Stuck at Open Position
  • 17405DFC Used to Evaluate Filter Clog
  • 17406Plausibility of the Absolute Difference Between the Battery Voltage and Power Stage Voltage of Backflow and Suction Line Heater
  • 17407Urea Supply Module: Plausibility of the Absolute Difference of Battery Voltage and the Powerstage of the Pressure Line
  • 17408Urea Supply Module: Plausibility of the Absolute Difference Between the Battery Voltage and Power Stage Voltage of Supply Module Heater
  • 17409Urea Supply Module: Reporting the Leakage in the System During No Dosing
  • 17410Error in Dosing Valve Plausibility at Low Voltage
  • 17411Urea Supply Module: Defective Pressure Reduction
  • 17412Urea Supply Module: High Threshold For Pressure Sensor Plausibility
  • 17413Urea Supply Module: Low Threshold For Pressure Sensor Plausibility
  • 17414Urea Supply Module: No Load Error
  • 17415Urea Supply Module: Over Temperature Error
  • 17416Urea Supply Module: Short Circuit to Battery Error
  • 17417Urea Supply Module: Short Circuit to Ground Error
  • 17420SRC High For Urea Pump Module Pressure Sensor
  • 17421SRC Low For Urea Pump Module Pressure Sensor
  • 17422Timer Error of ECU Off Time Counter
  • 17423SCR Inducement: Level 1 (Torque Reduction), Triggered by EGR Valve Blocked Fault
  • 17425SCR Inducement: Warning, Triggered by EGR Valve Blocked Fault
  • 17427SRC High For Air Temperature Sensor
  • 17428SRC Low For Air Temperature Sensor
  • 17429DFC is Set if the Cold Start is Detected
  • 17442Intake Throttle Valve: Permanent Governor Deviation For Valve, Max
  • 17443Intake Throttle Valve: Permanent Governor Deviation For Valve, Min
  • 17444Intake Throttle Valve: Open Load Error For Powerstage
  • 17446Intake Throttle Valve: Over Temperature Error For H-Bridge
  • 17447Intake Throttle Valve: Short Circuit to Battery on Out1 Error For H-Bridge
  • 17448Intake Throttle Valve: Short Circuit to Battery on Out2 Error For H-Bridge
  • 17449Intake Throttle Valve: Short Circuit to Ground on Out1 Error For H-Bridge
  • 1745Fuel Pressure Relief Valve Has Reached Maximum Allowed Open Time
  • 17450Intake Throttle Valve: Short Circuit to Ground on Out2 Error For H-Bridge
  • 17451Intake Throttle Valve: Short Circuit Over Load Error For H-Bridge
  • 17453Intake Throttle Valve: Under Voltage Error For H-Bridge
  • 17465Open Load Error in Powerstage of Urea Dosing Valve Actuator
  • 17466Short Circuit to Battery Error in Powerstage of Urea Dosing
  • 17467Short Circuit to Battery Error in Highside Powerstage of Urea Dosing Valve Actuator
  • 17468Short Circuit to Ground Error in Lowside Powerstage of Urea Dosing Valve Actuator
  • 17469Short Circuit to Ground Error in Highside Powerstage of Urea Dosing Valve Actuator
  • 17470HCU - Heater Control Unit For Reagent Dosing Lines: FET Error
  • 17476Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17477Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17478Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17479Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17480Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17481Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17482Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17483Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17484Diagnostic Fault Check For Supply Module Temperature Duty Cycle in Failure Range
  • 17485Urea Supply Module: No Load Error on Low Powerstage For Urea Back Flow Pump
  • 17486Urea Supply Module: Over Temperature Error on Low Powerstage For Urea Back Flow Pump
  • 17487Urea Supply Module: Short Circuit to Battery Error on Low Powerstage For Urea Back Flow Pump
  • 17488Urea Supply Module: Short Circuit to Ground Error on Low Powerstage For Urea Back Flow Pump
  • 1749Regeneration Ends Due to Time Exceeded
  • 17494Urea Quality Sensor: Short Circuit to Battery (Reported via Can Frame ComRX_CRI1)
  • 17495Urea Quality Sensor: Short Circuit to Ground (Reported via Can Frame ComRX_CRI1)
  • 17498Urea Quality Sensor: Sensor Internal Fault (via Can Frame ComRX_CRI1)
  • 175PTO Clutch Did Not Lock Up After 6 Seconds of Clutch Motion
  • 17500Urea Quality Sensor: Short to Battery of the Temperature Sensor Located in the Urea Quality Sensor (Reported via Can Frame ComRX_CRI1)
  • 17501Urea Quality Sensor: Short to Ground of the Temperature Sensor Located in the Urea Quality Sensor (Reported via Can Frame ComRX_CRI1)
  • 17504Urea Quality Sensor: Signal Fault of the Temperature Sensor Located in the Urea Quality Sensor (Reported via Can Frame ComRX_CRI1)
  • 17518SCR Inducement: Level 3 (Creep Mode), Triggered by EGR Valve Blocked Fault
  • 17524Hydrocarbon Level 1 Exceeded
  • 17525EGR Valve: OBD Monitoring Error
  • 17526SCR Inducement: Repeated Offenders is Active
  • 17527Regeneration Ends Due to Time Exceeded
  • 178PTO Speed Sensor Has Been Changed
  • 179PTO is Configured as a Two Speed and No Shaft Size Frequency Was Detected When the PTO Was Switched On
  • 17A4Intake Throttle Valve Position is Higher Than Expected
  • 17CECU Internal Failure - Injector CY33X Component
  • 17ENumber of Injections is Limited by Quantity Balance of High Pressure Pump
  • 17FMissing Adjustment Value Programming for Injector in Cylinder 1
  • 18Fender Switches and Automatic Rising Switch Not Connected Open Circuit or Short Circuit
  • 18001Hand Throttle Number 1 - Voltage Too Low
  • 18002Hand Throttle Number 1 - Voltage Too High
  • 18003Hand Throttle Number 2 - Voltage Too Low
  • 18004Hand Throttle Number 2 - Voltage Too High
  • 18005Engine Drop Control - Voltage Too Low
  • 18006Engine Drop Control - Voltage Too High
  • 18007Multi-Function Handle (MFH) - Switch Error
  • 18008Multi-Function Handle (MFH) - Voltage Too Low
  • 18009Multi-Function Handle (MFH) - Voltage Too High
  • 18010Powershift Throttle - Voltage Too Low
  • 18011Powershift Throttle - Voltage Too High
  • 18012CVT Mode Switch Error
  • 18013Multi-Function Handle (MFH) - Encoder Position Error
  • 18014Rear Hitch Position Control Potentiometer - Voltage Too High
  • 18015Rear Hitch Position Control Potentiometer - Voltage Too High
  • 18016Rear Hitch Draft Control Potentiometer - Voltage Too Low
  • 18017Rear Hitch Draft Control Potentiometer - Voltage Too High
  • 18018Rear Hitch Height Limit Potentiometer - Voltage Too Low
  • 18019Rear Hitch Height Limit Potentiometer - Voltage Too High
  • 18020Rear Hitch Drop Rate Potentiometer - Voltage Too Low
  • 18021Rear Hitch Drop Rate Potentiometer - Voltage Too High
  • 18022Rear Hitch Sensitivity Control Potentiometer - Voltage Too Low
  • 18023Rear Hitch Sensitivity Control Potentiometer - Voltage Too High
  • 18024EHR (Remote Valve) Flow Encoder Position Error
  • 18025Rear Hitch Slip Control Potentiometer - Voltage Too Low
  • 18026Rear Hitch Slip Control Potentiometer - Voltage Too High
  • 18027EHR (Remote Valve) 5 Lever Position - Voltage Too Low
Looking for a different New Holland Tractor code?Search the full fault-code database, or hand the code to the AI assistant for a plain-English explanation.