Case IH Fault Codes List: 3135 to 3236
Page 13 of 30 of the full Case IH fault code list (2,992 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.
Case IH codes 3135 to 3236
- 3135Cold Start Lamp – Short Circuit To Ground
- 3136Cold Start Lamp ‐ Excessive Temperature
- 3137High Pressure Pump Solenoid Valve - Open Circuit
- 3138Metering Unit - Temperature Too High
- 3139High Pressure Pump Solenoid Valve - Signal Too High
- 3140High Pressure Pump Solenoid Valve - Signal Too Low
- 3141Fuel Flow Setpoint Too Low - Fuel Metering Unit: Leakage Is Detected Based On Fuel Quantity Balance
- 3142High Pressure Test - Test Active
- 3143Grid Heater Switch Off Test (Voltage Drop Too High)
- 3144Grid Heater Switch Off Test (Voltage Drop Too Low)
- 3145Terminal 15 - No Signal
- 3146Water Sensor In The Fuel Filter : Water In Fuel Level Sensor Defect Detection
- 3147Oil Temperature Too High
- 3148Coolant Temperature Sensor Dynamic Test ‐ Failure (Minimum Temperature Raise Not Reached)
- 3149Coolant Temperature Sensor Test ‐ Failure (Minimum Temperature Not Reached)
- 3150System/Amber Warning Lamp – Short Circuit To Battery
- 3151System/Amber Warning Lamp – Short Circuit To Ground
- 3152System/Amber Warning Lamp ‐ No Load
- 3153System/Amber Warning Lamp ‐ Excessive Temperature
- 3154Grid Heater Relay - Short Circuit To Battery
- 3155Grid Heater Relay - Short Circuit To Ground
- 3156Grid Heater Relay - No Load
- 3157Engine Control Unit (ECU) Not Detected On The CAN bus Or The Engine Dataset Registration Information Was Not Available From The Engine Within The Time Required
- 3158Invalid ECM Checksum (The Engine Dataset Does Not Match The Dataset Registered For This Machine. Register The New Dataset If The Dataset Has Just Been Updated)
- 3159Invalid Engine Reference Torque
- 3160Fan Actuator – Short Circuit To Battery
- 3162Fan Actuator ‐ Open Load
- 3163Fan Actuator ‐ Temperature Too High
- 3164Fan Speed Sensor – Signal High
- 3165Fan Speed Sensor ‐ Signal Low
- 3166Fuel Filter Heater Relay - Short Circuit To Battery
- 3167Fuel Filter Heater Relay - Short Circuit To Ground
- 3168Fuel Filter Heater Relay ‐ Open Load
- 3169Fuel Filter Heater Relay - Signal Not Plausible
- 3170NH3 Sensor Value Not Mounted In Proper Position
- 3172Engine Coolant Temperature Has Exceeded The Pre-Warning Threshold
- 3173Engine Coolant Temperature Has Exceeded The Warning Threshold
- 3176High Pressure Pump Fuel Delivery Quantity in Over Run Exceeds a Maximum Threshold
- 3177Overspeed Detection In Component Engine Protection
- 3178Timeout Of CAN Message BC2EDC1
- 3179CAN Communication Failure Between Vehicle Controller and ECU - BC2ECU2 Message
- 3180CAN Communication Error Between Vehicle Control Module To EDC
- 3181Rail Pressure Positive Deviation Too High Concerning Set Point
- 3182Timeout Of CAN Message RxCCVS
- 3183Timeout Of CAN Message TSC1 ‐ VR (When Active)
- 3184Timeout Of CAN Message TSC1 ‐ VR (When Inactive)
- 3185Timeout Of CAN Message TF
- 3186Cylinder 1 Warning ‐ Fast Decay Error
- 3187Cylinder 1 Warning ‐ Application Dependent
- 3188Open Load Error Of An Cylinder 1 (Firing Order)
- 3189Cylinder 1 Warning ‐ Current Level Error
- 3190Cylinder 2 Warning ‐ Fast Decay Error
- 3191Cylinder 2 Warning ‐ Application Dependent
- 3192Open Load Error Of An Cylinder 4 (Firing Order)
- 3193Cylinder 2 Warning ‐ Current Level Error
- 3194Cylinder 3 Warning ‐ Fast Decay Error
- 3195Cylinder 3 Warning ‐ Application Dependent
- 3196Open Load Error of Injector in Cylinder 3
- 3197Cylinder 3 Warning ‐ Current Level Error
- 3198Cylinder 4 Warning ‐ Fast Decay Error
- 3199Cylinder 4 Warning ‐ Application Dependent
- 319CExhaust Flap Sticking or Internal Failure
- 319EDownstream NOx Sensor Values Are Not Plausible
- 3200Open Load Error Of An Cylinder 3 (Firing Order)
- 3201Cylinder 4 Warning ‐ Current Level Error
- 3202Cylinder 5 Warning ‐ Fast Decay Error
- 3203Cylinder 5 Warning ‐ Application Dependent
- 3204Cylinder 5 Warning - Open Load
- 3205Cylinder 5 Warning ‐ Current Level Error
- 3206Cylinder 6 Warning ‐ Fast Decay Error
- 3207Cylinder 6 Warning ‐ Application Dependent
- 3208Open Load Error Of An Cylinder 2 (Firing Order)
- 3209Cylinder 6 Warning ‐ Current Level Error
- 3210Injection Bank 1 Short Circuit Failure (All Injectors of The Same Bank Can Be Affected)
- 3211Bank 1 ‐ Injection Cable Short Circuit Low Side To Ground
- 3212Bank 1 ‐ Application Dependent
- 3213Bank 1 - Unclassifiable Error
- 3214Bank 1 Warning ‐ Application Dependent
- 3215Bank 1 Warning ‐ Application Dependent
- 3216Bank 1 Warning ‐ Open Load
- 3217Bank 1 Warning ‐ Unclassifiable Error
- 3218Injection Bank 2 Short Circuit Failure (All Injectors of The Same Bank Can Be Affected)
- 3219Bank 2 ‐ Injection Cable Short Circuit Low Side To Ground
- 3220Bank 2 ‐ Application Dependent
- 3221Bank 2 - Unclassifiable Error
- 3222Bank 2 Warning ‐ Application Dependent
- 3223Bank 2 Warning ‐ Application Dependent
- 3224Bank 2 Warning ‐ Open Load
- 3225Bank 2 Warning ‐ Unclassifiable Error
- 3226Messages SRA2EDC
- 3227Injection Processor (CY33X) Error ‐ Internal Reset / Clock Loss / Voltage Too Low
- 3228Injection Processor (CY33X) Error ‐ Unlocked / Initialization Failure
- 3229Injection Processor (CY33X) Error ‐ Injections Limited By Software
- 3230Injection Processor (CY33X) Error - SPI Communication Failure
- 3231Injection Processor Error ‐ Internal Reset / Clock Loss / Voltage Too Low
- 3232Injection Processor Error ‐ Unlocked / Initialization Failure
- 3233Injection Processor Error - Test Mode
- 3234Injection Processor Error - SPI Communication Failure
- 3235Injection Control - Number Of Injections Limited By Runtime
- 3236Number Of Injections Limited - By Quantity Balance
Other Case machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- New Holland Tractor3,475 codes
- FPT3,033 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- New Holland Combine2,274 codes
- John Deere Tractors1,884 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
- Deutz1,684 codes
- Perkins1,523 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.