HeavyEquipmentFix
Ask

Deutz Fault Codes List: 4207 to 516203

Page 8 of 17 of the full Deutz fault code list (1,684 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.

Deutz codes 4207 to 516203

  • 4207CAN torque speed control checksum error.
  • 421Offset angle between crank-and camshaft-sensor is too large.
  • 422Sensor Crankshaft Detection; Out of Range, Signal Disrupted; Disturbed Signal
  • 423Speed Detection; Out of Range, Signal Disrupted, Sensor Crankshaft Speed; No Signal
  • 43Misfire At Cylinder 6: Errormode Not Identifiable
  • 4334SCR system DEF pressure sensor short circuit or open circuit
  • 4335SCR system air pressure sensor - Short circuit or open circuit
  • 4337SCR system AdBlue temperature sensor short circuit to ground
  • 4340DEF line heater 1 critical high output current
  • 4342DEF line heater 2 critical high output current
  • 4344DEF line heater 3 critical high output current
  • 4360Exhaust gas temp sensor upstream SCR - Supply voltage out of range
  • 4363Exhaust gas temperature sensor downstream SCR supply voltage out of range
  • 4364SCR system - Very low conversion efficiency
  • 4380InpScrNhlllDwn1 - Electrical error
  • 4383InpScrNhlllDwn1 - Heater error
  • 44Misfire At Cylinder 7: Errormode Not Identifiable
  • 4413Exhaust gas temp sensor 2 supply voltage out of range
  • 4419SCR system 2 very low conversion efficiency
  • 4490Air filter combi sensor specific ambient humidity error
  • 45Sensor battery voltage error; signal range check is high.
  • 455PWM-Signal Fan, Open Circuit Or Short-Circuit Ground
  • 457PWM-Signal fan, short-circuit to battery.
  • 458PWM-Signal Fan, Open Circuit Or Short Circuit To Ground
  • 459Fan speed sensor, electrical error, signal disturbed or very low fan speed.
  • 46Sensor battery voltage error; signal range check is low.
  • 460Sensor error fan speed. Signal range check high or engine speed resp. fan speed big.
  • 461Sensor Error Fan Speed, Signal Voltage Low (Possible Short Circuit) Or Fan Speed Too Low
  • 462High fan speed, warning threshold exceeded.
  • 463High fan speed, shut off threshold exceeded.
  • 464Sensor Error Water, Signal Voltage High (Possible Open Circuit)
  • 465Sensor Error Water in Fuel; Signal Voltage Low (Possible Short Circuit)
  • 47Misfire At More Cylinder: Errormode Not Identifiable
  • 472Sensor Error Low Fuel Pressure; Signal Voltage High (Possible Open Circuit)
  • 473Sensor Error Low Fuel Pressure; Signal Voltage Low (Possible Short Circuit)
  • 474Low fuel pressure, warning threshold exceeded.
  • 475Low fuel pressure, shut off threshold exceeded.
  • 4765Exhaust gas temperature sensor upstream DOC supply voltage out of range
  • 48Request Of Engine Off: Erratic, Intermittent Or Incorrect
  • 4812Piston cooling oil supply valve short circuit to battery
  • 483Fuel temperature not plausible.
  • 486Gearbox Oil Temperature; Short Circuit To Battery Or Broken Harness
  • 487Sensor error gearbox oil temperature, signal range check low.
  • 488Physical range check high for exhaust gas temperature upstream (SCR-CAT)
  • 489Shutoff condition, No detail information!
  • 5Set Point 1 Foot Pedal Circuit
  • 50Rack Position Circuit Shutdown
  • 500HCI dosing valve (DV1); overcurrent at the end of the injection phase.
  • 501HCI Dosing Valve (DV1); Power Stage Over Temperature
  • 502HCI dosing valve (DV1): Short circuit to battery
  • 503Short circuit to battery high side, HCI dosing valve (DC1).
  • 504HCI dosing valve (DV1): Short circuit to ground.
  • 505HCI dosing valve (DV1): Short circuit high side powerstage.
  • 506Sensor HCI dosing valve (DV1): downstream pressure: Plausibility error.
  • 508HCI dosing valve (DV1) downstream pressure: Physical range check high. Shut off regeneration.
  • 511HCI dosing valve (DV1) downstream pressure: Physical range check low. Shut off regeneration.
  • 514Sensor Error HCI Dosing Valve (DV1) Downstream Pressure; Signal Voltage High (Possible Open Circuit)
  • 515Sensor Error HCI Dosing Valve (DV1) Downstream Pressure; Signal Voltage Low (Possible Short Circuit)
  • 516096Accelerator pedal sensor plausibility error
  • 516097Accelerator pedal sensor 1 short circuit or open circuit
  • 516098Accelerator pedal sensor 2 short circuit or open circuit
  • 516099Internal temperature error of air filter combi sensor
  • 516101Air filter pressure switch short circuit to ground or open circuit
  • 516104Supply voltage out of range in alternator frequency input
  • 516106Short circuit to ground or open circuit in alternator output voltage
  • 516114Testbench CAN communication error (Id 585).
  • 516115Testbench CAN communication error (Id 594).
  • 516117Common rail PCV opened due to overpressure
  • 516118Common rail plausibility error of VCV current
  • 516121Common rail pressure remains above set point
  • 516122Common rail pressure remains below set point
  • 516123Common rail start pressure too low
  • 516131Common rail pressure sensor no signal variation
  • 516135Digital output 1 short circuit to battery (high side)
  • 516136Digital output 2 short circuit to battery
  • 516137Lamp output 1 short circuit to battery (high side)
  • 516138Lamp output 2 short circuit to battery (high side)
  • 516142EGR auto calibration error.
  • 516143EGR auto learning error.
  • 516144EGR learnt values lost.
  • 516149ECU invalid IO-config file received from Master
  • 516150Engine protection power reduction due to high intake temp
  • 516151Exhaust flap - Control deviation error
  • 516152Exhaust brake valve 1 - Hardware error
  • 516153Exhaust flap - Invalid reference position
  • 516154Exhaust flap - Overtemperature warning
  • 516177Multi-stage switch speed selector supply voltage out of range
  • 516179Start of injection late post injection too close
  • 516180Start of injection post injection too close to main injection
  • 516181Start of injection pre injection too close to main injection
  • 516182Start of injection early pre injection too close
  • 516184Dashboard communication error.
  • 516189Imbalanced engine speed deviation too high
  • 516195Generator Set Controller communication error.
  • 516198NH3 sensor - Communication error
  • 516199InpScrNhlllDwn1 - High concentration warning
  • 516200InpScrNhlllDwn1 - Internal error
  • 516201InpScrNhlllDwn1 - Error
  • 516202NH3 sensor - Module-sensor communication error
  • 516203NOx sensor downstream SCR - Invalid sensor status
Looking for a different Deutz code?Search the full fault-code database, or hand the code to the AI assistant for a plain-English explanation.