- 516204NOx sensor upstream SCR - Invalid sensor status
- 516205NOx sensor bank installation error
- 516207Particulate filter DPF - Soot load estimation too high
- 516209Pressure control valve current above set point
- 516211Pressure control valve PWM signal high limit
- 516212Pressure control valve PWM signal plausibility error
- 516223Terminal 15 ECU internal safety error
- 516225Engine PME CAN ECU internal safety error
- 516227Starter ECU internal safety error
- 516228Safety PME CAN communication error
- 516229SCR system - SCR air valve defect
- 516230SCR system - Defrosting actuator error (AdBlue)
- 516231SCR system - Defrosting error (AdBlue)
- 516232SCR system - Defrosting sensor error (AdBlue)
- 516233SCR system - Feedback control max saturation reached
- 516235Ventilation error in SCR system (AdBlue)
- 516236SCR system (DEF injector) - AdBlue injection path blocked
- 516237SCR system (DEF injector) - Air path blocked
- 516238SCR system air switch valve high output current
- 516245Smart sensor supply relay - Short circuit to battery
- 516250Vehicle speed velocity deviation too high
- 516251Volume control valve current above set point
- 516253Volume control valve PWM signal plausibility error
- 516265SCR system - Last ventilation of AdBlue line interrupted
- 516281Aftertreatment protection power reduction due to high temp
- 516283Engine protection power reduction boost pressure too high
- 516284Engine protection power reduction boost pressure too low
- 516300Exhaust flap management auto calibration error
- 516301Exhaust flap management auto learning error
- 516302Exhaust flap management learnt values lost
- 516318Wastegate valve - Load is short circuited
- 516330Volume control valve - Electrical error
- 516333Lamp output 3 short circuit to battery (high side)
- 516341Aftertreatment control module - Emission error
- 516346Heating flange status input 1 short circuit to battery (high side)
- 516354Engine power reduced for turbocharger protection.
- 516355ECU communication error with aftertreatment module.
- 516361Oil level sensor high electrical error
- 516362Oil level sensor medium electrical error
- 516363Oil level sensor low electrical error
- 516367SCR system - Inverted Air Pressure and Adblue Pressure at the Adblue Pump
- 516369Starter 2 locked due to overtemperature
- 516401Injector 1 small quantity injection correction failed
- 516402Injector 2 small quantity injection correction failed
- 516403Injector 3 small quantity injection correction failed
- 516404Injector 4 small quantity injection correction failed
- 516405Injector 5 small quantity injection correction failed
- 516406Injector 6 small quantity injection correction failed
- 516407Injector 7 small quantity injection correction failed
- 516408Injector 8 small quantity injection correction failed
- 516409Injector 9 small quantity injection correction failed
- 516410Injector 10 small quantity injection correction failed
- 516411Injector 11 small quantity injection correction failed
- 516422Pressure control valve load short circuited
- 516424Starter inhibition due to short circuit
- 516425Starter inhibition due to short circuit
- 516428Air pressure sensors plausibility error
- 516429Injector 1 minimal injection pulse calculation error
- 516430Injector 1 minimal injection pulse error
- 516435Injector 12 minimal injection pulse calculation error
- 516436Injector 12 minimal injection pulse error
- 516451Injector 2 minimal injection pulse calculation error
- 516452Injector 2 minimal injection pulse error
- 516455Injector 3 minimal injection pulse calculation error
- 516456Injector 3 minimal injection pulse error
- 516457Injector 4 minimal injection pulse calculation error
- 516458Injector 4 minimal injection pulse error
- 516459Injector 5 minimal injection pulse calculation error
- 516460Injector 5 minimal injection pulse error
- 516461Injector 6 minimal injection pulse calculation error
- 516462Injector 6 minimal injection pulse error
- 516463Injector 7 minimal injection pulse calculation error
- 516464Injector 7 minimal injection pulse error
- 516465Injector 8 minimal injection pulse calculation error
- 516466Injector 8 minimal injection pulse error
- 516467Injector 9 minimal injection pulse calculation error
- 516468Injector 9 minimal injection pulse error
- 516471Exhaust flap - No sensor position data available
- 516479Lamp output 4 short circuit to battery (high side)
- 516481Lamp output 5 short circuit to battery (high side)
- 516483Accelerator applied while engine brake activated
- 516487Aftertreatment control module - Error detected
- 516488Engine CAN open circuit on engine connector
- 516489Engine CAN open circuit on machine connector.
- 516494ECU CAN1 message received after post drive
- 516495ECU runtime reached max time without reset
- 516510Speed sensors position inversion error
- 516513NOx sensor bank drift error
- 516514SCR system - Catalyst cleaning request in not safe condition
- 516515Engine stop during manual regeneration of DPF
- 516516Particulate filter DPF - Max time without regeneration exceeded
- 516527Auxiliary accelerator short circuit to ground or open circuit
- 516542Primary Cab Controller communication error.
- 516544Starter activated but engine not started
- 516545Engine oil level sensors plausibility error
- 516547Signal Ground Error - Electrical error of SGND
- 516553SCR system - Critical overload of accumulate carbon in catalyst
- 516564Passenger-Operator Climate Control communication error.
- 516566Engine oil service interval approaching
- 516570Auxiliary accelerator 2 short circuit to ground or open circuit
Other Deutz machine types
Fault code lists by brand
- CAT8,286 codes
- Volvo6,508 codes
- New Holland Tractor3,475 codes
- FPT3,033 codes
- Case IH2,992 codes
- Bobcat2,653 codes
- Challenger Tractor2,434 codes
- New Holland Combine2,274 codes
- John Deere Tractors1,884 codes
- Case Wheel Loader1,859 codes
- John Deere Engines1,853 codes
- Cummins1,847 codes
- Challenger Rubber Track Tractor1,747 codes
- Volvo Wheel Loader1,726 codes
Safety-critical: confirm before use
Safety first: park on level ground, stop the engine, and secure the machine before any inspection. Thresholds, component locations, wire numbers, fuse locations, and reset procedures can vary by model, configuration, and serial number. Confirm them in the service documentation for your exact machine.