HeavyEquipmentFix
Ask

New Holland Tractor Fault Codes List: 68B6 to 8043

Page 30 of 35 of the full New Holland Tractor fault code list (3,475 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.

New Holland Tractor codes 68B6 to 8043

  • 68B6DEF Supply Module Supply Voltage Control Relay Short Circuit to Battery
  • 68DThrottle Valve Actuator Control Circuit Low Side Shorted to Battery
  • 69Hitch Position Control Lever Potentiometer Failure
  • 69BAShort Circuit to Battery of DEF Pressure Line Heater Actuator Powerstage
  • 6A14Intake Air Heater Actuator is Shorted to Battery Voltage
  • 6A52Short Circuit to Battery Error For Low Voltage System
  • 6A67EGR Valve Control Circuit High Side Shorted to Battery
  • 6B22Starter Relay Low Side Driver Circuit Short to Battery Failure
  • 6B67EGR Valve Control Circuit Low Side Shorted to Battery
  • 6C5ADEF Reverting Valve Driver Circuit Short to Battery Failure
  • 6D4ECU Internal Failure 'WDA Active' Reported Due to Errors in Query/Response Communication
  • 6EB6Short Circuit to Battery Error in Powerstage of Urea Dosing Valve Actuator
  • 6FB6Short Circuit to Battery Error in Highside Powerstage of Urea Dosing Valve Actuator
  • 7Hitch Raise/Lower Solenoids Circuit Failed Open, or Short to Ground
  • 70Battery Voltage is Too Low for Clutch Solenoid Operation
  • 7014Differential Lock Command Switch Error - Switch Disconnected
  • 7017Differential Lock Solenoid Valve Open Circuit or Short to Ground
  • 7024Steering Angle Sensor Not Calibrated
  • 7032Steering Angle Sensor - Signal Too Low
  • 7033No Difflock Pressure
  • 7034Difflock Pressure Switch - Stuck On
  • 7100Autoguidance Isolation Solenoid - Disconnected/Over Temperature
  • 7101Autoguidance Isolation Solenoid - Solenoid Return Short to Battery
  • 7102Autoguidance Isolation Solenoid - Solenoid Return Short to Ground
  • 7103Steering Angle Plausibility Error (Auto Guidance Only)
  • 7104Timeout of Steering Angle Sensor CAN Message
  • 7116Injection Bank 1 Short Circuit Failure (All Injectors of the Same Bank Can be Affected)
  • 717ADEF Dosing Valve Actuator Short Circuit to Ground in High Side Failure
  • 71C6Short Circuit to Ground Error in Lowside Powerstage of Urea Dosing Valve Actuator
  • 72Hot Transmission Oil Temperature
  • 7216Injection Bank 2 Short Circuit Failure (All Injectors of the Same Bank Can be Affected)
  • 723ADEF Supply Module Pump Motor Short Circuit to Ground Failure
  • 7268SCG Error on the Turbocharger PWM Output Powerstage
  • 72CGlow Plug 1 Control Circuit Shorted to Ground
  • 72C6Short Circuit to Ground Error in Highside Powerstage of Urea Dosing Valve Actuator
  • 73Software is Out of Calibration Mode and Park Brake Request is Still Active
  • 734EDEF Quality Sensor Internal Failure (Short Circuit to Ground Error)
  • 737ADEF Dosing Valve Actuator Short Circuit to Ground Failure
  • 73E4Short Circuit to Ground on Out1 Error For H-Bridge
  • 74The Park Brake is Commanded ON and Gear is Engaged, but There is No Park Brake Request from Calibration
  • 74B5Fuel Filter Heater Actuator is Shorted to Ground
  • 74E4Short Circuit to Ground on Out2 Error For H-Bridge
  • 75Hard Wired Alternator Engine RPM Does Not Match ICU Alternator Engine RPM
  • 7522Auxiliary Power Relay Low Side Driver Circuit Short to Ground Failure
  • 753AShort Circuit to Ground of DEF Supply Module Heater Actuator Powerstage
  • 7555Fuel Metering Unit is Shorted to Ground at the High Side
  • 7562Glow Plug 1 Control Circuit Shorted to Ground
  • 757DSupply UB1 Circuit Short to Ground Failure
  • 759ADEF Tank Heater Actuator Short Circuit to Ground Failure
  • 76Hard Wired Alternator Engine RPM Does Not Match Governor Engine RPM
  • 7662Glow Plug 3 Control Circuit Shorted to Ground
  • 76D6Short Circuit to Ground Error on Low Powerstage For Urea Back Flow Pump
  • 77No Signal from Wheel Speed Sensor
  • 7755Fuel Metering Unit is Shorted to Ground at the Low Side
  • 7762Glow Plug 4 Control Circuit Shorted to Ground
  • 777DSupply UB2 Short to Ground Failure
  • 78Transmission Regulated Pressure Accumulator is Discharged
  • 7822Starter Relay High Side Driver Circuit Short to Ground Failure
  • 7833Fan Clutch Solenoid Short Circuit to Ground Failure
  • 7862Glow Plug 2 Control Circuit Shorted to Ground
  • 78BThrottle Valve Actuator Position Sensor Voltage is Higher Than Expected
  • 78DThrottle Valve Actuator Control Circuit Supply Voltage Too Low
  • 79Engine RPM from the Alternator is Measured Too High
  • 794EShort to Ground of the Temperature Sensor Located in the Urea Quality Sensor (Reported via CAN Frame COMRX_CRI1)
  • 797DSupply UB3 Short to Ground Failure
  • 79B6DEF Supply Module Supply Voltage Control Relay Short Circuit to Ground
  • 7A61Auxiliary Power Relay High Side Driver Circuit Short to Ground Failure
  • 7ABAShort Circuit to Ground of DEF Pressure Line Heater Actuator Powerstage
  • 7B52Short Circuit to Ground Error For Low Voltage System
  • 7BATimeout Error of CAN-Receive-Frame CM1BC
  • 7C14Intake Air Heater Actuator is Shorted to Ground
  • 7C22Starter Relay Low Side Driver Circuit Short to Ground Failure
  • 7C67EGR Valve Control Circuit High Side Shorted to Ground
  • 7D5ADEF Reverting Valve Driver Circuit Short to Ground Failure
  • 7D67EGR Valve Control Circuit Low Side Shorted to Ground
  • 80Wheel Speed Sensor is Measured Too High
  • 8001Front PTO CAB Switch is on during Tractor Power up
  • 8002Front PTO Brake Output - Short Circuit to 12V
  • 8003Front PTO Brake Output - Open Circuit or Short Circuit to Ground
  • 8004Front PTO Solenoid Open Circuit or Short Circuit to Ground, or AD12VU2 Voltage is Low
  • 8005Front PTO Solenoid Circuit Short Circuit to B+ When Front PTO is in the Off State
  • 8006Low Side Driver is Stuck On and No Current is Sensed
  • 8007Front PTO Switch is in the On Position When the Engine is Off
  • 8008Short Circuit to Ground or Open Circuit on Electromagnetic Clutch
  • 8009Low Side Front PTO Solenoid Connected Permanently to Ground
  • 801012VU2 Voltage Supply is Low
  • 8011Battery Voltage Low
  • 8013Front PTO Shift - Switch Open Circuit
  • 8014Front PTO Shift - Switch Short Circuit
  • 8017Short Circuit Between Terminals of Electromagnetic Clutch Slip Detector
  • 8024Front PTO Shift - Not Calibrated
  • 8027Front PTO Speed Sensor - Open Circuit
  • 8032Short Circuit to +12 V or Open Circuit on Electromagnetic Clutch Slip Detector
  • 8033Front PTO Switch in Cab Normally Closed - Open Circuit
  • 8034Front PTO Fender Switch - Open Circuit/Short to Ground
  • 8035Front PTO Fender Switch - Input Short to 12V
  • 8036Front PTO Failure to Start
  • 8037Front PTO Cab Normally Open Switch - Stuck Closed
  • 8042Front PTO Management Switch - Short Circuit
  • 8043Front PTO Fender Switch - Stuck On
Looking for a different New Holland Tractor code?Search the full fault-code database, or hand the code to the AI assistant for a plain-English explanation.