Page 32 of 35 of the full New Holland Tractor fault code list (3,475 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.

New Holland Tractor codes 9E6E to F012

  • 9E6ECan Timeout Error From Upstream NOx Sensor
  • 9E8CHydrocarbon Level 2 Exceeded
  • 9ECATimeout Error of Can Receive Frame HCU Data
  • 9F5ADEF Reverting Valve Driver Circuit Over Temperature Failure
  • A36EDownstream NOx Sensor Internal Failure (Heater Performance Plausibility Error)
  • A66EUpstream NOx Sensor Internal Failure (Heater Performance Plausibility Error)
  • BFBATimeout Error of Can Receive Frame HCU Data
  • CHHot Oil Warning: Displayed Above 100 Degrees C
  • CLCold Oil Warning: Displayed Below 20 Degrees C
  • E126ECU Internal Failure - Injector CY33X Component
  • E13DECU Internal Failure - Loss of Synchronization to MM From CPU
  • E16DThere Was an Error During Write/Read EEPROM Operation
  • E16EDownstream NOx Sensor Internal Failure (Heater Open Circuit Error)
  • E18EDownstream NOx Sensor Internal Failure (Open Circuit Error)
  • E196ECU Internal Failure - Injector CY33X Component
  • E1DDECU Internal Failure - Post Injection Quantity
  • E1FDECU Internal Failure - Fuel Calibration
  • E21DECU Internal Failure - NTP Error in ADC Monitoring
  • E22DECU Internal Failure - Sensor 5 Volt Supply 1
  • E23DECU Internal Failure - ECU Shutdown Test Failure
  • E26DECU Internal Failure - EEPROM Erase Error
  • E26EDownstream NOx Sensor Internal Failure (Heater Short Circuit Error)
  • E28EDownstream NOx Sensor Internal Failure (Short Circuit Error)
  • E2DDECU Internal Failure - Post Injection Shut-Off Failure
  • E31DECU Internal Failure - ADC Test
  • E32DECU Internal Failure - Sensor 5 Volt Supply 2
  • E336ECU Internal Failure - Internal SPI Injector Related Timeout Error
  • E33DECU Internal Failure - Wrong Set Response Time
  • E36DECU Internal Failure - EEPROM Read Error
  • E3C6FET Error
  • E3DDPost Injection Efficiency Failure
  • E41DECU Internal Failure - Voltage Ratio in ADC Monitoring
  • E42DECU Internal Failure - Sensor 5 Volt Supply 3
  • E43DECU Internal Failure - SPI Errors During MoCSOP Execution
  • E46DECU Internal Failure - EEPROM Write Error
  • E46EUpstream NOx Sensor Internal Failure (Heater Open Circuit Error)
  • E48EUpstream NOx Sensor Internal Failure (Open Circuit Error)
  • E4DDFuel Injection Requested During Overrun
  • E51DECU Internal Failure - Query/Response Communication Errors
  • E52DECU Internal: Error Sensor Supplies Voltage Tracker
  • E536Engine Speed Limitation via Fuel Injection Cut Off is Active
  • E53DECU Internal Failure - Undervoltage Monitoring Error
  • E55DECU Temperature Sensor Error Detected
  • E56DECU EEPROM Memory Failure - EEPDATA1 Block
  • E5B1ECU Internal Failure - Accelerator Pedal Position Sensor
  • E5DDECU Internal Failure - Injection Quantity Correction
  • E61DECU Internal Failure - SPI Communication Error
  • E62D12 V Sensor Supply 1 Voltage is Too High
  • E63DECU Internal Failure - WDA is Not Working Correctly
  • E64DECU Internal Failure
  • E69DECU Internal Failure - Timeout in the Shut Off Path Test Error
  • E6DDECU Internal Failure - Rail Pressure Plausibility
  • E6DEDiaNH3 Sensor Open or Short in Measuring Cell Circuit
  • E71DECU Internal Failure - ROM Error
  • E72D12 V Sensor Supply 1 Voltage is Too Low
  • E73DECU Internal Failure - Alarm Task Period Error
  • E79DECU Internal Failure - Overvoltage Monitoring Error
  • E7DDECU Internal Failure - Torque Request Comparison
  • E7DEDiaNH3 Sensor Open or Short in Measuring Cell Circuit
  • E812ECU Internal Failure - Calculated Engine Speed
  • E81DECU Internal Failure - 'WDA Active' Reported Due to Errors in Query/Response Communication
  • E82DInternal 12 V Supply Voltage is Too High
  • E83DECU Internal Failure - Positive Test Failed
  • E86APower Stage Error in HCU for DEF Back Flow Line Heater
  • E8DDECU Internal Failure - Torque Request Due to Fuel Pressure Exceeds Maximum Torque Limit
  • E91DECU Internal Failure - 'ABE Active' Reported Due to Undervoltage Detection
  • E92DInternal 12 V Supply Voltage is Too Low
  • E96APower Stage Error in HCU For DEF Supply Module Heater
  • E98EUpstream NOx Sensor Values are Not Plausible
  • E9DDECU Internal Failure - Torque Request Due to Air Control Exceeds Maximum Torque Limit
  • E9DENH3 Sensor Open in Heater Circuit Causing Underheating
  • EA1DECU Internal Failure - 'ABE Active' Reported Due to Overvoltage Detection
  • EA2DECU Internal: Timer Error of ECU Off Time Counter
  • EADDECU Internal Failure - Torque Request Exceeds Maximum Torque Limit
  • EADENH3 Sensor Open or Short in Temperature Cell Circuit
  • EB1DECU Internal Failure - 'WDA/ABE Active' Reported
  • EBDDECU 5 Volt Supply Voltage is Higher Than Expected
  • EBDENH3 Sensor Open or Short in Trim Resistor Circuit
  • EC36ECU Internal Failure - Fuel Injection Energizing Time is Not Plausible
  • EC8AHeater Control Unit Detected Error with Non Volatile Memory (NVM) - Internal System Failure
  • ECDDECU 5 Volt Supply Voltage is Lower Than Expected
  • ED1DECU Internal Failure - Software Resets in DSM 0
  • ED2DCan Communication Failure - External Torque/Speed Checksum and Counter
  • ED36ECU Internal Failure - Fuel Injection Energizing Phase is Not Plausible
  • ED8AHeater Control Unit Detected an Over Temperature Error - Internal System Failure
  • EE1DECU Internal Failure - Software Resets in DSM 1
  • EE36Fuel Injection Correction Has Exceeded a Minimum Limit
  • EE8AHeater Control Unit Detected an Over Voltage Error - Internal System Failure
  • EEA8Heater Control Unit Detected an Over Voltage Error - Internal System Failure
  • F0013-Point Hitch Module Transient Reset
  • F0023-Point Hitch Module Analog to Digital Channel Lockup
  • F003True Ground Speed is Greater Than Axle Speed
  • F004Axle Speed is Greater Than Maximum Speed
  • F006Slip Limit Potentiometer Failed Low
  • F007Slip Limit Potentiometer Failed High or Open
  • F008Raise Switch and Work Switch Both High
  • F009Fender 3-Point Hitch Switches - Raise/Lower Both Engaged
  • F010Height Limit Potentiometer Failed Low or Short
  • F011Height Limit Potentiometer Failed High or Open
  • F012Drop Rate Potentiometer Failed Low or Short