  • 4350Rear Remote No.6 ‐ Valve Spool Not Calibrated
  • 4351Rear Remote No.7 ‐ Valve Spool Not Calibrated
  • 4352Rear Remote No.8 ‐ Valve Spool Not Calibrated
  • 4353EHR FB 1High Err
  • 4354EHR FB 1 Low Err
  • 4355EHR FB 3 High Err
  • 4356EHR FB 3 Low Err
  • 4357EHR Implement Lower Error
  • 4358EHR Implement Raise Error
  • 4700EEPROM Corrupted
  • 4701EEPROM Data Write Unsuccessful
  • 471012V Key Power Lines: Voltage Too High
  • 471112V Key Solenoid Activation: Voltage Too High
  • 471212V Key Solenoid Activation: Voltage Too Low
  • 471312V Key Solenoid Activation: Voltage Too Low
  • 472012V Key Lines and 12V Key Solenoid Activation Line Not Powered Together (12V Key Low and 12V Key Solenoid Activation High)
  • 472112V Key Lines and 12V Key Solenoid Activation Line Not Powered Together (12V Key High and 12V Key Solenoid Activation Low)
  • 4722Hydraulic Motor Engagement Switch: Both Lines Active
  • 4723Hydraulic Motor Engagement Switch: Both Lines Not Active
  • 4724X-Axis Selection Switch: Both Lines Active
  • 4725Y-Axis Selection Switch: Both Lines Active
  • 4726X-Axle Selection Switch: Both Lines Not Active
  • 4727Y-Axle Selection Switch: Both Lines Not Active
  • 4730Joystick: Signal From X-Axis Short to 5V
  • 4731Joystick: Signal From Y-Axis Short to 5V
  • 4732Hydraulic Motor: Signal From Potentiometer Short to 5V
  • 4733Joystick: Signal From X-Axis Short to Ground
  • 4734Joystick: Signal From Y-Axis Short to Ground
  • 4735Hydraulic Motor: Signal From Potentiometer Short to Ground or Open Circuit
  • 4736Proportional Valve X-Axis: Spool Position Pot Signal Short to 12V
  • 4737Proportional Valve X-Axis: Spool Position Pot Signal Short to 5V
  • 4738Proportional Valve X-Axis: Spool Position Pot Signal Short to Ground
  • 4739Proportional Valve Y-Axis: Spool Position Pot Signal Short to 12V
  • 4740Proportional Valve Y-Axis: Spool Position Pot Signal Short to 5V
  • 4741Proportional Valve Y-Axis: Spool Position Pot Signal Short to Ground
  • 4750Spool X-Axis Moves in the Opposite Way Respect to Joystick Activation (Spool Low While Joystick Rise)
  • 4751Spool X-Axis Moves in the Opposite Way Respect to Joystick Activation (Spool Rise While Joystick Low)
  • 4752Spool Y-Axis Moves in the Opposite Way Respect to Joystick Activation (Spool Low While Joystick Rise)
  • 4753Spool Y-Axis Moves in the Opposite Way Respect to Joystick Activation (Spool Rise While Joystick Low)
  • 4760At Least One Joystick Axis and/or One Spool Position Sensor are Not in Neutral Position At Startup
  • 4761Wrong Signal From Joystick X-Axis or Spool Position Sensor X or Inconsistency Between Joystick X-Axis and SPSL1
  • 4762Wrong Signal From Joystick Y-Axis or Spool Position Sensor X or Inconsistency Between Joystick Y-Axis and SPSL2
  • 4763Wrong Signal From Potentiometer, or Wrong MSH Switch Cycle
  • 4770Proportional Valve X-axis: No Current Feedback
  • 4771Proportional Valve Y-axis: No Current Feedback
  • 4772Proportional valve hydraulic motor: No current feedback
  • 4773Proportional Valve X-axis: Overload Current Feedback
  • 4774Proportional Valve Y-axis: Overload Current Feedback
  • 4775Proportional Valve Hydraulic Motor: Overload Current Feedback
  • 4776Proportional Valve X-axis: Current Feedback Too High
  • 4777Proportional Valve Y-axis: Current Feedback Too High
  • 4778Proportional Valve Hydraulic Motor: Current Feedback Too High
  • 4790Proportional Valve X-Axis: Valve MMX-A Solenoid Short to 12V
  • 4791Proportional Valve X-Axis: Valve MMX-B Solenoid Short to 12V
  • 4792Proportional Valve Y-Axis: Valve MMY-A Solenoid Short to 12V
  • 4793Proportional Valve Y-Axis: Valve MMY-B Solenoid Short to 12V
  • 4794Motor Mode: Proportional Valve Solenoid Short to 12V
  • 4795ON/OFF Valve Y-Axis: Valve A1/B1 Solenoid Short to 12V
  • 4796ON/OFF Valve Y-Axis: Valve A2/B2 Solenoid Short to 12V
  • 4797ON/OFF Valve X-Axis: Valve A3/B3 Solenoid Short to 12V
  • 4798ON/OFF Valve X-Axis: Valve A4/B4 Solenoid Short to 12V
  • 4799Motor Mode: Enable Valve Solenoid Short to 12V
  • 4800Proportional Valve X-Axis: Valve MMX-A Solenoid Short to Ground
  • 4801Proportional Valve X-Axis: Valve MMX-B Solenoid Short to Ground
  • 4802Proportional Valve Y-Axis: Valve MMY-A Solenoid Short to Ground
  • 4803Proportional Valve Y-Axis: Valve MMY-B Solenoid Short to Ground
  • 4804Motor Mode: Proportional Valve Solenoid Short to Ground
  • 4805ON/OFF Valve Y-Axis: Valve A1/B1 Solenoid Short to Ground
  • 4806ON/OFF Valve Y-Axis: Valve A2/B2 Solenoid Short to Ground
  • 4807ON/OFF Valve X-Axis: Valve A3/B3 Solenoid Short to Ground
  • 4808ON/OFF Valve X-Axis: Valve A4/B4 Solenoid Short to Ground
  • 4809Motor Mode: Enable Valve Solenoid Short to Ground
  • 4810Proportional Valve X-Axis: Valve MMX-A Solenoid Open Circuit
  • 4811Proportional Valve X-Axis: Valve MMX-B Solenoid Open Circuit
  • 4812Proportional Valve Y-Axis: Valve MMY-A Solenoid Open Circuit
  • 4813Proportional Valve Y-Axis: Valve MMY-B Solenoid Open Circuit
  • 4814Motor Mode: Proportional Valve Solenoid Open Circuit
  • 4815ON/OFF Valve Y-Axis: Valve A1/B1 Solenoid Open Circuit
  • 4816ON/OFF Valve Y-Axis: Valve A2/B2 Solenoid Open Circuit
  • 4817ON/OFF Valve X-Axis: Valve A3/B3 Solenoid Open Circuit
  • 4818ON/OFF Valve X-Axis: Valve A4/B4 Solenoid Open Circuit
  • 4819Motor Mode: Enable Valve Solenoid Open Circuit
  • 4820Proportional Valve X-Axis: Valve MMX-A Solenoid Unstable Current
  • 4821Proportional Valve X-Axis: Valve MMX-B Solenoid Unstable Current
  • 4822Proportional Valve Y-Axis: Valve MMY-A Solenoid Unstable Current
  • 4823Proportional Valve Y-Axis: Valve MMY-B Solenoid Unstable Current
  • 4824Motor Mode: Proportional Valve Solenoid Unstable Current
  • 4825ON/OFF Valve Y-Axis: Valve A1/B1 Solenoid Unstable Current
  • 4826ON/OFF Valve Y-Axis: Valve A2/B2 Solenoid Unstable Current
  • 4827ON/OFF Valve X-Axis: Valve A3/B3 Solenoid Unstable Current
  • 4828ON/OFF Valve X-Axis: Valve A4/B4 Solenoid Unstable Current
  • 4829Motor Mode: Enable Valve Solenoid Unstable Current
  • 4830Engine Rpm via CAN Line: Timeout Reception
  • 4840Sensor Supply Line 5V: Value Too High
  • 4841Sensor Supply Line 5V: Value Too Low
  • 4842Sensor Supply Signal: Open Circuit, Towards +5V
  • 4843Sensor Supply Signal: Open Circuit, Towards Ground
  • 4851Proportional Valve X-Axle: Short Circuit Between HSD A and HSD B
  • 4852Proportional Valve X-Axle: Short Circuit Between HSD A and HSD B and Open Circuit On HSD A
  • 4861Proportional Valve Y-Axle: Short Circuit Between HSD A and HSD B