HeavyEquipmentFix
Ask

New Holland Fault Codes List: 3555 to 3789

Page 10 of 15 of the full New Holland fault code list (1,492 codes). Each entry is the code as the machine reports it and what the manufacturer data says it means.

New Holland codes 3555 to 3789

  • 3555CAN Message Timeout SCR2 (From DCU) ‐ CAN Timeout
  • 3557Info: Humidity Sensor Possibly Saturated With Water Droplets ‐ Signal Ratio Above Limit
  • 3558Info: Humidity Sensor Possibly Saturated With Water Droplets ‐ Signal Ratio Below Limit
  • 3561NOx value Not Plausible (After Treatment Plausibility)
  • 3565Urea Quality And Urea Warning Level 1
  • 3569Urea Quality And Urea Warning Level 2
  • 3573Urea Quality And Urea Warning Level 3
  • 3577DM1DCU SPN1 Message ‐ Error In DCU Active
  • 3581Performance Limit Active Due To Either Stage ‐ Performance Limitation Active
  • 3616Torque Limitation Due to Turbo Charger Protection
  • 3648Turbocharger: P2 Pressure Errors in PCR - Pressure Deviation Too High
  • 3650Battery Voltage: Source High for Battery Voltage Sensor
  • 3651Battery Voltage: Source Low for Battery Voltage Sensor
  • 3655Torque Limitation, Engine Protection: General Report of the Event of Torque Limitations
  • 3656Torque Limitation, Engine Protection: Torque Limitation Caused by Particulate FiIter
  • 3657CAN Bus Received Frames: Timeout Error of CAN Receive-Frame CM1BC
  • 3663EGR Command Saturation Over Higher Threshold
  • 3664EGR Command Saturation Over Lower Threshold
  • 3665Permanent Governor Deviation for Valve
  • 3666Permanent Governor Deviation for Valve
  • 3667Exhaust Gas Recirculation (EGR) Valve Actuator - Open Circuit at Power Stage
  • 3668Exhaust Gas Recirculation (EGR) Valve Actuator Over-Temperature at Power Stage
  • 3669Exhaust Gas Recirculation (EGR) Valve Actuator - Short Circuit to Battery on Out1 of Power Stage
  • 3670Exhaust Gas Recirculation (EGR) Valve Actuator - Short Circuit to Battery on Out2 of Power Stage
  • 3671Exhaust Gas Recirculation (EGR) Valve Actuator - Short Circuit to Ground on Out1 of Power Stage
  • 3672Exhaust Gas Recirculation (EGR) Valve Actuator - Short Circuit to Ground on Out2 of Power Stage
  • 3673Exhaust Gas Recirculation (EGR) Valve Actuator - Short Circuit at Power Stage
  • 3674Exhaust Gas Recirculation (EGR) Valve Actuator Under-Voltage at Power Stage
  • 3675Long Time EGR Valve Drift at Closed Position
  • 3676Exhaust Gas Recirculation (EGR) Valve Actuator - Position Sensor Voltage Too High
  • 3677Exhaust Gas Recirculation (EGR) Valve Actuator - Position Sensor Voltage Too Low
  • 3680Injection Cut Off: Injection Cut Off Demand for Shut Off Coordinator
  • 3688Water Sensor in the Fuel Filter: WIF Sensor Check is Failed
  • 3689Glow Plug Control Module - Faulty Diagnostic Data Transmission or Protocol Fault
  • 3691Glow Plug Control Module - Open Circuit at Power Stage
  • 3692Glow Plug Control Module - Over-Temperature at Power Stage
  • 3693Glow Plug Control Module - Short Circuit to Battery at Power Stage
  • 3694Glow Plug Control Module - Short Circuit to Ground at Power Stage
  • 3699EEPROM: Error in EEPROM Block EEPData1 SD Correction Cannot be Calculated
  • 3702Injection Control: Detection of Failed Engine Start
  • 3703Injection Control: Check of Minimum Rail Pressure
  • 3704Injector Adjustment Programming: Check of Missing Injector Adjustment Value Programming
  • 3705Injector Adjustment Programming: Check of Missing Injector Adjustment Value Programming
  • 3706Injector Adjustment Programming: Check of Missing Injector Adjustment Value Programming
  • 3707Lambda Sensor - Open Circuit at the Nernst Cell Pin
  • 3708Lambda Sensor - Open Circuit at the Pump Current Pin
  • 3709Lambda Sensor - Open Circuit at the Virtual Ground Pin
  • 3710Lambda Sensor - Signal Not Plausible
  • 3711Lambda Sensor - Short Circuit to Battery at Heater Power Stage
  • 3712Lambda Sensor - Short Circuit to Ground at Heater Power Stage
  • 3713Lambda Sensor - Open Circuit at Heater Power Stage
  • 3714Lambda Sensor - Oxygen Ratio Signal Too High During Calibration
  • 3715Lambda Sensor - Oxygen Ratio Signal Too Low During Calibration
  • 3716Lambda Sensor - Oxygen Ratio Signal Too High
  • 3720Lambda Sensor - Supply Voltage Too Low
  • 3721Lambda Sensor: Fault Check to Indicate SPI Chip Error of Lambda Sensor
  • 3722Lambda Sensor - Calculated Temperature Too High
  • 3723Lambda Sensor - Calculated Temperature Too Low
  • 3724Lambda Sensor - Short Circuit to Battery
  • 3725Lambda Sensor - Short Circuit to Ground
  • 3727Info: Low Oil Viscosity
  • 3728Info: Too Low Oil Viscosity
  • 3735High Pressure Pump Metering Solenoid Valve Over-Temperature
  • 3736Lambda Sensor - Oxygen Ratio Out of Range
  • 3737Lambda Sensor - Over-Temperature at Heater Power Stage
  • 3738Analog Digital Convertor (ADC): Diagnostic Fault Check to Report Multiple Errors While Checking the Complete ROM-Memory
  • 3739Power Stages, Injector: Loss of Synchronization
  • 3740Power Stages, Injector: DFC to Set a Torque Limitation Once an Error is Detected Before MoCSOP's Error Reaction is Set
  • 3741Power Stages, Injector: Wrong Set Response Time
  • 3742Power Stages, Injector: Too Many SPI Errors During MoCSOP Execution
  • 3743Power Stages, Injector: Diagnostic Fault Check to Report the Error in Under Voltage Monitoring
  • 3744Power Stages, Injector: Diagnostic Fault Check to Report the Error in Over Voltage Monitoring
  • 3745Power Stages, Injector: Diagnostic Fault Check to Report That WDA is Not Working Correctly
  • 3746Power Stages, Injector: OS Timeout in the Shut Off Path Test - Failure Setting the Alarm Task Period
  • 3747Power Stages, Injector: Diagnostic Fault Check to Report That the Positive Test Failed
  • 3748Power Stages, Injector: Diagnostic Fault Check to Report the Timeout in the Shut Off Path Test
  • 3750Injection Control: Error in the Plausibility of the Injection Energizing Time
  • 3751Injection Control: Error in the Plausibility of the Start of Energizing Angles
  • 3752Zero Fuel Calibration (ZFC): Error in the Plausibility of the Energizing Times of the Zero Fuel Quantity Calibration
  • 3753Level 2 Monitoring: Diagnostic Fault Check to Report the Error Due to Injection Quantity Correction
  • 3754Level 2 Monitoring: Diagnostic Fault Check to Report the Plausibility Error in Rail Pressure Monitoring
  • 3755Level 2 Monitoring: Diagnostic Fault Check to Report the Error Due to Torque Comparison
  • 3756Level 2 Monitoring: Diagnosis Fault Check to Report the Demand for Normal Mode Due to an Error in the Post Injection 2 Quantity
  • 3757Level 2 Monitoring: Diagnosis Fault Check to Report the Error to Demand for an ICO Due to an Error in the Post Injection 2 Shut Off
  • 3758Level 2 Monitoring: Diagnosis Fault Check to Report the Error to Demand for an ICO Due to an Error in the Post Injection 3 Efficiency Factor
  • 3759Level 2 Monitoring: Diagnosis of Curr Path Limitation Forced by ECU Monitoring Level 2
  • 3760Level 2 Monitoring: Diagnosis Air Path Limitation Due to a Functional Control Unit Monitoring Forced by ECU Monitoring Level 2
  • 3761Level 2 Monitoring: Diagnosis Quantity Path Limitation Due to a Functional Control Unit Monitoring (Level 2)
  • 3762Level 2 Monitoring - Sensor Supply Voltage Too High
  • 3763Level 2 Monitoring - Sensor Supply Voltage Too Low
  • 3764Main Relay ECU - Early Opening Fault
  • 3766Diesel Particulate FiIter Pressure Sensor: Fault Check for the Pressure Sensor Plausibility
  • 3767ECU Internal: Diagnostic Fault Check to Report 'WDA Active' Due to Errors in Query/Response Communication
  • 3768ECU Internal: Diagnostic Fault Check to Report 'ABE Active' Due to Under Voltage Detection
  • 3769ECU Internal: Diagnostic Fault Check to Report 'ABE Active' Due to Overvoltage Detection
  • 3770ECU Internal: Diagnostic Fault Check to Report 'WDA/ABE Active' Due to Unknown Reason
  • 3773Turbocharger: Under Boost Detected in Pressure Charger Regulator
  • 3786Diesel Particulate FiIter (DPF): Signal Range Check How Resistance of the Particulate Filter - High
  • 3787Diesel Particulate FiIter (DPF): Signal Range Check How Resistance of the Particulate Filter - Very High
  • 3789Regeneration Duration Exceeds Maximum Allowed Duration
Looking for a different New Holland code?Search the full fault-code database, or hand the code to the AI assistant for a plain-English explanation.

Other New Holland machine types